PCAN-Router Pro FD – User Manual
10
2.1
Power Supply
For the operation of the PCAN-Router Pro FD a voltage source with
nominal 12 V DC is required, 8 to 32 V are possible. The input is
electronically protected with reverse polarity and overvoltage
protection.
Note:
The scope of delivery does not include a power supply
unit for the power supply of the device. The device is not
supplied via the USB connection to the PC.
The connection is made via the mating connector supplied (3-pole,
type: Phoenix Contact MC1,5/3-STF-3,81) to which you can screw
cable strands. The polarity is as follows:
Figure 3: Power connector
Pin
Function
Description
1
Wake-up
3 to 32 V DC required for wake-up signal
2 V
b
(8-32V)
Power supply with 8 to 32 V DC
3 GND Ground
Pin 1 is only necessary for transceivers without wake-up function
(see section 4.1) to switch on the device.
2.2
CAN Connection
A high-speed CAN bus (ISO 11898-2) is connected to the 9-pin
D-Sub connector. The CAN assignment corresponds to the
CiA
®
303-1 specification.