background image

GeniusNM-3G Installation Guide Rev 1 PN 3300043 26/01/17

Genius NM-3G

Installation Guide

NM

Содержание Genius NM-3G

Страница 1: ...GeniusNM 3G Installation Guide Rev 1 PN 3300043 26 01 17 Genius NM 3G Installation Guide NM...

Страница 2: ...or more extensive user operation directions we recommend you download the User Manual from the website Please visit www peakscientific com downloads to download the full User Manual for your gas gener...

Страница 3: ...CAUTION notice denotes a hazard It calls attention to an operating procedure process or similar which if not correctly performed or adhered to could cause damage to the Generator or the Application D...

Страница 4: ...ns Cable C19 04 1025 x1 EU Mains Cable C19 04 1026 Fittings Kit x3m 1 4 Teflon Tubing 00 1266 x3m 6mm OD x 4mm ID PE 00 1282 x1 8mm Hex Key 00 0007 x1 Flow Control SIlencer 02 1096 x1 1 4 Compression...

Страница 5: ...rea 1 2 First remove the compressor transit brackets These can be accessed by removing the generator top panel Using a Pozidrive 1 screwdriver turn each screw shown 90 to the right The screws are spri...

Страница 6: ...g it off the spade connector on the panel 4 Remove the 8 mounting screws circled then lift the transit brackets out starting with the two on the centre compressor Do not discard the transit brackets o...

Страница 7: ...m Push Fit Fitting 02 4600 and attach to the Drain port at the rear of the generator Fit the Flow Control SIlencer 02 1096 to the Nitrogen port 02 4600 Re attach the top panel Ensuring the earth lead...

Страница 8: ...lock 90 to the right 00 0007 Connect the 6mm PE Tubing 00 1282 to the 6mm Push Fit Fitting 02 4600 Fit the other end of the tubing to a suitable drain connection or container The container MUST NOT ha...

Страница 9: ...hand side panel ensuring you disconnect the earth lead from the panel 10 9 Select the appropriate mains cable from the fittings kit and plug the IEC 60320 C19 cable into the mains input at the rear of...

Страница 10: ...using the switch on the front panel 230VAC 50 60Hz Plug the mains cable into the corresponding 230VAC 50 60Hz single phase power supply CAUTION ensure the correct cable has been selected for your ele...

Страница 11: ...ge that is being supplied to the generator Note the displayed voltage If the voltage is 219V or less we would highly reccomend fitting a transformer This can be ordered directly from Peak 06 3200 Dual...

Страница 12: ...Page 12 16 15 Remove the mains cable completely from the power supply CAUTION Re attach the right side panel to the generator ensuring the earth lead is re connected and the lock is secured...

Страница 13: ...Page 13 18 17 With the side panels securely re attached the mains power supply can be re connected CAUTION Switch the generator ON using the switch on the front panel...

Страница 14: ...tart until the user has pressed the confirm button The unit will now begin an Installation Diagnostics Sequence This will take approx 20 mins to complete PLEASE CONFIRM THAT ALL TRANSIT BRACKETS HAVE...

Страница 15: ...confirm has been pressed Once diagnostics have been completed the unit will take a couple of minutes to be ready for use Please ensure that any tubing connected to the drain port is secure and that th...

Страница 16: ...beeps to signify the unit is ready for use and a reminder to register the unit will be displayed When an option has been selected the unit will display NORMAL OPERATION Peak Scientific NM 3G NORMAL OP...

Страница 17: ...25 Leave the generator switched on for a period of 30 minutes to purge the system NM 30 minutes After 30 minutes of running the generator can be turned OFF Allow the stored gas in the internal tanks t...

Страница 18: ...ads 0 the Flow Control Silencer 02 1096 can be removed from the generator s Nitrogen port Select the Compression Fitting 02 4421 and connect to the NITROGEN port Attach the Teflon tubing 00 1266 to th...

Страница 19: ...ch the generator power ON using the switch on the front panel The unit will now display PLEASE WAIT while sufficient operating pressures are reached This may take up to 20 minutes Peak Scientific NM 3...

Страница 20: ...ssure gauges will again gradually increase to the factory set pressures Once the output and tank pressures are up to operating conditions the unit will display NORMAL OPERATION Peak Scientific NM 3G N...

Страница 21: ...Page 21 33 CONGRATULATIONS Your Peak Scientific gas generator is now fully installed operational and ready to supply gas on demand to your instrument NM...

Страница 22: ...ument then attention needs to be paid to pressure drops that could occur The maximum distance away from the instrument the generator can be placed still using 6mm 4mm internal diameter or 3 16 interna...

Страница 23: ...e date of factory dispatch Go Online or Complete and Return You can register for your FREE 12 month Warranty with ease online at www peakscientific protected Alternatively you can send the completed f...

Страница 24: ...o download the full User Manual for your gas generator Peak Scientific has highly trained fully certified Field Service Engineers located in over 20 countries across every continent around the world T...