19
OPERATION
1.
Set the pressure regulator to about 50 PSI and slide the sensor to a
central position along the track. Test operation by moving your hand past
the sensor while keeping away from any moving parts, the pads should
close rapidly. The pads can also be activated manually by pressing the
green button on either side. The middle green LED on the panel will illumi-
nate when the machine is clamped
Hold the red button to release the pads from the closed position. Repeat
this a few times to familiarize yourself with the operation
2.
Test the operation of the drafting gates by moving the switch from the
closed position to the open position. Move the switch back to the closed
position until the gate closes before triggereing the other gate
Reverse gate operation when using switch by swapping the two 8mm
hoses under the Draft Module
Open
Gate
Closed
Open
Gate
3.
Test the operation of the REAR ACCESS MODULE gates, a little oil on the
latch and hinges will help free up the gate operation. To close, lift up on the
latch and pull gate backwards. The gate assembly should swing to the
closed position. Lock into place by dropping the latch into the slot in the
floor.
FIG.19
FIG.20
Содержание IMMOBILIZER SHEEP WORKER