Touch io Instruction Manual
Touch io Wiring & LED Color Indicators
For
touch io
and door controller wiring, the image illustrates the reader’s wiring configuration to the door
controller.
NOTE
: For UL certified wire installations, all wire running from a
Single io
door controller to a lock, strike,
or reader device must be less than 98.5 feet (30 meters).
Touch io Reader
- Mounted at the door with a 22/5 or 22/6 wire running to the door controller. Wire the
reader to the controller as shown above.
Secondary Reader
- If an additional
touch io
reader is used, it should be mounted at a door with a 22/5 or
22/6 wire running to the controller as shown above.
Piezo (buzzer)
- Optional piezo trigger wiring for a tamper or door prop alarm connects to (-) on the AUX
relay. The piezo buzzer can be controlled with software rules.
NOTE
: Check polarity and voltage carefully prior to powering the controller.
Page 15