GRL-PCIE5-CEM-RXA User Guide and MOI
Rev7.0
© Granite River Labs 2022 Version 7.0, June 2022. Updated 06.29.2022
Page 31 of 123
CTLE Scan Start & End EQ
Gain (dB)
Select the optimized CTLE Equalization Gain setting index to be used based
on the CTLE model to measure the Eye area.
Use Real Edge
Se
lect ‘True’
to use Real Edge connection for test setup on the Oscilloscope.
Note: This setting is only applicable for the Keysight Scope.
ISI Scan Range
Select the scan range during ISI calibration.
Eye Width & Eye Height
Min / Max Limit
Enter the limits for maximum and minimum eye calibration values.
Number Of UI
Enter the number of unit interval (UI) samples to acquire during calibration.
Final Eye Convergence
Select either a Strict or Loose method to be applied in the calculation for the
final calibrated eye.
If the SigTest method is selected:
Parallel SigTest Run
Select ‘True’ to enable running the SigTest in parallel mode with the Long
Channel TP2 calibration.
Maximum Thread Spawn
Set the maximum process threads to generate for checking the Rx device
functionality during Long Channel TP2 calibration.
SigTest N Acquisition
Enter the number of measurements to acquire when running SigTest over the
Long Channel TP2 calibration.
Eye Width/Height SigTest
N Acquisition
Enter the number of measurements to acquire when running SigTest for the
Eye calibration.
DM Optimization SJ
Sweep / Amplitude
Select the SJ scan range or amplitude for DM optimization calibration.
DM Optimization Target
Select the Eye Width or Eye Height to prioritize as a target during DM
optimization calibration
DM Fine Tune
Select ‘
True
’ to
fine tune DM in smaller steps to find the lowest DM value
possible with Eye Height and Eye Width still in range.
If the Seasim method is selected:
Seasim Template
Enter the Seasim template file to be used.
Final Eye Amplitude Cal
On First Pass
Select ‘True’ to enable calibration for final eye amplitude to be performed
upon the first successful calibration run.
Intrinsic Noise
Set the intrinsic noise/jitter (if required) to be used in the Seasim calculation.
PW RJ & PW DDJ
Enter the pulse width random jitter or deterministic jitter.
4.7
Configure Calibration Target Values
For debugging purposes ONLY, the default calibration target values can be changed for the RJ, SJ,
DM and CM calibration. To do this, select
from the menu to access the Calibration page.