background image

 

 

©  PCE Instruments 

 

Switching on and off  

To switch the meter on and off, press the on/off switch. The measurement is made after a few 
seconds. To switch the meter off again, press the on/off switch again. 

Backlight  

When the meter is switched on, the backlight is activated. To switch off the backlight, press and 
hold the "ECO" key for two seconds. To switch the backlight back on, press and hold the "ECO" 
key again for two seconds.  

Making a measurement  

To  make  a  measurement,  first  connect  the  earthing  cable  to  the  meter  and  to  an  earthed 
conductor.  Then  switch  on  the  meter.  The  measurement  will  start  after  a  short  time.  Point  the 
measuring device at the object to be measured. You have reached the correct distance as soon 
as the lasers cross. Now you can read the measured value.  

Zeroing  

To zero the meter, first ground it with the earthing cable. Then switch on the meter and wait until 
the reading has stabilised. Then press the zero key to set the displayed reading to zero.  

 
NOTE: 

Make sure that there is no static charge on the sensor side. This can influence zeroing.  
 
 
 

 

Содержание PCE-SFS 10

Страница 1: ...r PCE SFS 10 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 29...

Страница 2: ...afety notes 1 2 Specifications 2 3 Delivery scope 2 4 Device description 3 4 1 Display description 6 5 Battery information 6 6 Switching on and off 7 7 Backlight 7 8 Making a measurement 7 9 Zeroing 7...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...n 0 1 RH Accuracy 4 5 RH Further specifications Response time 100 ms Audible alarm when the meter is switched on 5 seconds before automatic power off when measurement range is exceeded Automatic power...

Страница 5: ...E Instruments 3 4 Device description No Description 1 Housing 2 Display 3 On and off switch 4 HOLD key to freeze the display 5 ECO key for switching the backlight on and off 6 Status display 1 2 3 4 5...

Страница 6: ...PCE Instruments 4 No Description 7 Temperature and humidity sensor 8 Service interface No Description 9 Alignment laser 10 Radiation sensor 7 8 9 10...

Страница 7: ...PCE Instruments 5 No Description 11 Zero key for setting the zero point 12 Earth connection No Description 13 Nameplate 14 Battery compartment 11 12 13 14...

Страница 8: ...sly shown on the display Battery status display Meaning Battery is fully charged Battery is partially discharged Battery almost discharged The battery should be replaced promptly Battery is discharged...

Страница 9: ...g a measurement To make a measurement first connect the earthing cable to the meter and to an earthed conductor Then switch on the meter The measurement will start after a short time Point the measuri...

Страница 10: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 11: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Отзывы: