background image

 

 

©  PCE Instruments 

 

10.4 

Pulse Mode Operation 

User can also program the pulse mode and set it for alternating times from 30 secs to 99 secs. 
 
First set the required speed and total run time for operation. Then hold down the “Pulse” button 
to select the cycle time of stirring. The cycle time value will appear on the right side display, “SEC” 
will appear in left side display and pulse LED will start blinking indicating that the user can now 
modify the cycle time. Use increment or decrement button to modify the cycle time between 30 
seconds to 99 seconds. Once the cycle time is modified, it will automatically save after 5 blinks. 
Press the “Pulse Button” once to START pulse mode operation with the modified cycle time. 
 
Press “Pulse” again to stop pulse mode operation. User can also Press “Start / Stop” to STOP 
ongoing pulse mode operation. 

11  Troubleshooting 

Any type of malfunction during operation can be identified by error an message on display. 
Proceed as follows in such cases.

 

 

1. Problem : No Display

 

Root Cause : No main power connection

 

Solution : 1. Check main power is available 

2. Check that power adaptor is working properly and it is properly connected at both 
    ends. 
3. If the problem still persists then contact PCE Instruments. 

 

2. Problem : Err 2 
Root Cause : Motor blockage/over load/fail, Encoder sensor fail

 

Solution : 1. First switch off the equipment, plug it out and plug it in again. 

2. If the problem still persists then contact PCE Instruments. 

12  Maintenance and cleaning 

1. 

Before  cleaning  the  device,  allow  the  instrument  to  attain  room  temperature  remove  the 
power cord from the mains. 

2. 

To clean the housing of the device from dyes, building materials or cosmetic materials use 
isopropyl alcohol as a cleaning agent. 

3. 

To  clean  the  housing  of  the  device  from  food  materials  or  fuels,  use  water  containing 
detergent as cleaning agent. 

4. 

Wear proper protective gloves while cleaning the instrument. 

5. 

Be careful that no liquid enters the device during cleaning. 

6. 

Kindly contact suppliers before using any other methods for cleaning. 

 

 

Содержание PCE-MSR 150

Страница 1: ...rrer PCE MSR 150 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last chang...

Страница 2: ...tents 3 7 Device description 4 8 Installation 5 8 1 Location and mounting 5 8 2 Connecting power adaptor 5 9 User interface and display 6 10 Operation 8 10 1 Switching on the device 8 10 2 Setting Tim...

Страница 3: ...in explosive atmospheres The measurement range as stated in the specifications must not be exceeded under any circumstances Place the device on a flat stable clean non slippery and fire proof surface...

Страница 4: ...diation through surrounding temperature etc Abrasion of the dispersion equipment or the rotating accessories can get into the medium you are working on The chemical reaction of PTFE can occur when in...

Страница 5: ...ts repair For repair please contact the supplier 4 Technical specifications Motor DC Max Stirring Quantity on Equip H2O 19 l Speed range 200 2200 RPM Speed control 10 RPM Step Accuracy 20 RPM Time ran...

Страница 6: ...PCE Instruments 4 7 Device description Front side 1 Stainless steel top plate 3 Start stop button 2 Digital display 4 On off button Rear Side 1 Power Socket...

Страница 7: ...ly Avoid installing on a slippery surface or surface prone to vibration 1 Ideal ambient temperature is 25 C 1 C avoid placing the unit in direct sunlight 2 Keep clearance of at least 20 cm from all si...

Страница 8: ...RPM 2 Time Press Time to select time value Then press to set Time value in minutes 3 Mins Hours Press Mins Hours to display time either in Minutes or Hour s 4 Pulse Press Pulse to activate the pulse m...

Страница 9: ...PCE Instruments 7...

Страница 10: ...e value by pressing button When time button is pressed the Mins display will blink indicating the time value is selected Once time value is selected single press will increase or decrease time value b...

Страница 11: ...error an message on display Proceed as follows in such cases 1 Problem No Display Root Cause No main power connection Solution 1 Check main power is available 2 Check that power adaptor is working pro...

Страница 12: ...ies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012...

Страница 13: ...3 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info pce instruments co uk info pce italia it www pce instruments com us www pce instruments com english ww...

Отзывы: