PCE-MFM 3000

G ( Gauss), mT ( milli Tesla ), USB/RS232

MAGNETIC 

FIELD 

METER

Your purchase of this
AC/DC MAGNETIC METER
marks a step forward for
you into the field of
precision measurement.
Although this METER is a
complex and delicate
instrument, its durable
structure will allow many
years of use if proper
operating techniques are
developed. Please read the
following instructions
carefully and always keep
this manual within easy
reach.

       OPERATION MANUAL

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

 

www.pce-instruments.com

PCE Instruments UK Ltd.

Unit 11 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

 [email protected]

Содержание PCE-MFM 3000

Страница 1: ...are developed Please read the following instructions carefully and always keep this manual within easy reach OPERATION MANUAL PCE Americas Inc 711 Commerce Way Suite 8 Jupiter FL 33458 USA From outsi...

Страница 2: ...r 4 3 12 RS 232 Output Terminal 4 3 13 Reset button 4 3 14 DC 9V Power Adapter Input Socket 4 3 15 Stand 4 3 16 Tripod Fix Nut 4 3 17 Battery Compartment Cover 4 3 18 Battery Cover Screw 4 4 MEASURING...

Страница 3: ...ompensation Zero button for DC AC magnetic function Separate probe easy operation and convenient for remote measurement Data hold function for freezing the desired value on display Records Maximum and...

Страница 4: ...x 0 1 mT G Range 1 1 500 0 G x 0 1 G Range 2 15 000 G x 1 G Accuracy DC 5 rdg 10 digit at 23 5 AC 5 rdg 20 digit Frequency AC measurement Response 50 Hz 60 Hz Sensor Hall sensor Temp Probe head build...

Страница 5: ...9V adapter input AC DC power adapter is optional Power Current Approx DC 15 mA Weight Approx 275 g 0 61 LB include probe Dimension Main instrument 198 x 68 x 30 mm 7 8 x 2 7 x 1 2 inch Probe 195 x 25...

Страница 6: ...Button 3 6 Mode Button DC AC Button SET Button 3 7 Input socket 3 8 Probe Handle 3 9 Probe Sensing Head 3 10 Probe Plug 3 11 Probe Head Cover 3 12 RS 232 Output Terminal 3 13 Reset button 3 14 DC 9V P...

Страница 7: ...2 0 mT c1 0 G c2 0 AC 0 AC 0 0 mT d1 0 G d2 0 AC 0 AC Note a1 screen is ready for DC 0 1 mT resolution measurement b1 screen is ready for DC 0 01 mT resolution measurement c1 screen is ready for AC 0...

Страница 8: ...field measurement Display will show AC indicator Display will not show N S indicator 4 unit selection How to select the unit mT G the procedures please refer to chapter 5 2 Change the unit mT G page 9...

Страница 9: ...HOLD symbol Press the Hold Button once again will release the data hold function 4 3 Data Record Max Min reading The data record function records the maximum and minimum readings Press the REC Button...

Страница 10: ...easurement and execute the RECORD function it can not change from the North pole to South pole or from the South pole to North pole during the measurement It can make the measurement under the same po...

Страница 11: ...After select the desiring function YES or no press the REC Button 3 4 Fig 1 to save the function with default 5 2 Select the measurement unit to mT or G When the lower display show unit 1 Use the REC...

Страница 12: ...ia a 3 5 mm terminal 3 12 Fig 1 The data output is a 16 digit stream which can be utilized for user s specific application A RS232 lead with the following connection will be required to link the instr...

Страница 13: ...e 9600 Parity No parity Data bit no 8 Data bits Stop bit 1 Stop bit 7 BATTERY REPLACEMENT 1 When the left corner of LCD display show it is necessary to replace the battery However in spec measurement...

Страница 14: ...old for example the key button can not be operated Then make the system RESET will fix the problem The system RESET procedures will be either following method During the power on use a pin to press th...