background image

©  PCE Instruments 

 
 

5.3 

Settings 

Use the settings menu to change the settings for the offset, sleep mode or Bluetooth mode. The 
pressure gauge will save your settings to the internal memory. 
 

Option 

Menu item 

Settings 

Offset 

Offset 

T1 or T2 

Bluetooth 

bt 

On (Bluetooth activated) 
Off (Bluetooth deactivated) 

Sleep mode 

SLP 

On (sleep mode activated) 
Off (sleep mode deactivated) 

 
When the device is in the se

ttings menu, the display will show “SETUP”. Hold the “Setup” key 

for three seconds to enter or leave settings mode. 

5.3.1 

Change settings 

Use the “Units ▲” or “Units▼” keys to navigate to the setting that needs to be 
changed.  

Press ”Enter” to choose the corresponding setup option.  

Press “Units ▲” or “Units▼” to select the desired setting.  

Press “Enter” to save your changes.  

5.3.2 

Offset 

The primary display shows the temperature in correlation with the offset. You can save 
individual offsets for T1 and T2.  

5.3.3 

Zero the pressure range 

To ensure accurate readings, zero the pressure range before each measurement. Make sure 
that the meter and / or the pressure hoses are open and not connected to any source of 
pressure. 

Press and hold the “Hold” key for three seconds and the instrument will set the 

environmental pressure as the zero point. 

5.3.4 

Automatic shutdown 

If sleep mode is activated, the pressure gauge will shut down after 30 minutes of inactivity. In 
order to activate or deactivate sleep mode, you need to go into the settings menu and then 
press the “Units ▲” and “Units▼” key to go to the submenu “SLP”. Then press “Enter” and you 
will be able to choose between “On” and “Off”. Press “Enter” to save your changes.  

5.3.5 

Bluetooth 

The Bluetooth module can be connected with MFi (Made for iPod 7 iPhone / iPad Logo) 
equipment and Bluetooth standard SPP equipment and send the measured data to Android and 
Apple iOS devices via Bluetooth. It transfers data with a 2.4 GHz ISM band and it is compatible 
with the Bluetooth core specifications version 3.0 +EDR. 
The Bluetooth function can be activated or deactivated as described in chapter 

¡Error! No se 

encuentra el origen de la referencia.

 

 

Содержание PCE-HVAC 4

Страница 1: ...PCE Instruments Pressure Gauge Man metro digital PCE HVAC 4 Manual de Instrucciones User Manual ESVersi n 1 0 ENVersion 1 0 ltima modificaci n last change 12 Julio 2019...

Страница 2: ...ciones 8 5 2 1 Mantener valor indicado Error Marcador no definido 5 2 2 Indicar MIN MAX y valor AVG Wert 8 5 2 3 Utilizar Offset 8 5 3 Ajustes Error Marcador no definido 5 3 1 Cambiar opci n de ajuste...

Страница 3: ...15 5 1 Measurement 15 5 1 1 Pressure 15 5 1 2 Temperature 15 5 2 Further functions 15 5 2 1 Hold function 15 5 2 2 Min Max Avg function 15 5 2 3 Use the offset 15 5 3 Settings 16 5 3 1 Change setting...

Страница 4: ...tilice el medidor con las manos mojadas No se permite realizar modificaciones t cnicas en el aparato El aparato s lo debe limpiarse con un pa o No utilice productos abrasivos ni productos de limpieza...

Страница 5: ...vado Fuera de rango de medida Se indica OL o OL Dimensiones 206 x 95 x 45 mm Peso 435 g Presi n Tomas de presi n 7 16 UNF Rango de medida 14 500 psi 96 4000 kPa 0 96 34 47 bar 28 5 1018 0 inHg 72 2585...

Страница 6: ...3 Descripci n de sistema 3 1 Pantalla 1 Indicaci n P1 P2 P1 P2 2 Presi n P1 P2 P1 P2 3 Unidad de presi n 4 T1 T2 T1 T2 y unidad de temperatura 5 S mbolo HOLD SETUP MAX MIN AVG 6 Temperatura ambiental...

Страница 7: ...cero la presi n atmosf rica Tecla T1 T2 Pulse la tecla para cambiar entre T1 T2 y T1 T2 Tecla Setup Pulse la tecla para encender la luz de fondo Pulse de nuevo el bot n para apagar la luz de fondo Ma...

Страница 8: ...nciones 5 2 1 Funci n Hold 1 Pulse la tecla Hold para congelar el valor medido en la pantalla La pantalla mostrar HOLD 2 Pulse de nuevo la tecla Hold para desactivar la funci n HOLD 5 2 2 Funci n MIN...

Страница 9: ...uraci n est desactivada en el modo MIN MAX 5 3 2 Offset La pantalla principal muestra la temperatura m s el offset Se pueden guardar Offsets individuales para T1 y T2 5 3 3 Puesta a cero el rango de p...

Страница 10: ...midor final est legalmente obligado a devolverlas Las bater as usadas se pueden devolver en cualquier punto de recogida establecido o en PCE Ib rica Puede enviarlo a PCE Ib rica SL C Mayor 53 Bajo 025...

Страница 11: ...ture The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should o...

Страница 12: ...35 g 2 2 Technical specifications for pressure Pressure connections 7 16 UNF Measurement range 14 500 psi 96 4000 kPa 0 96 34 47 bar 28 5 1018 0 inHg 72 2585 cmHg Resolution 0 1 psi inHg 1 kPa cmHg Ac...

Страница 13: ...m description 3 1 Display 1 P1 P2 P1 P2 display 2 P1 P2 P1 P2 pressure 3 Pressure unit 4 T1 T2 T1 T2 and temperature unit 5 Symbols for activated functions HOLD SETUP MAX MIN AVG 6 Ambient temperature...

Страница 14: ...ressing the key again Hold the key for three seconds to zero the atmospheric pressure T1 T2 key Press this key to switch between T1 T2 and T1 T2 Setup key Press this key to activate or deactivate the...

Страница 15: ...rmocouple 5 2 Further functions 5 2 1 Hold function Press the Hold key to freeze the displayed value By pressing the Hold key again the Hold function will be deactivated 5 2 2 Min Max Avg function Pre...

Страница 16: ...urate readings zero the pressure range before each measurement Make sure that the meter and or the pressure hoses are open and not connected to any source of pressure Press and hold the Hold key for t...

Страница 17: ...f the European Parliament applies Due to the contained pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to com...

Страница 18: ...80 98703 0 Telefono 39 0583 975 114 Fax 1 561 320 9176 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 info pce americas com info industrial needs com info pce italia it www pce instruments com us www pce i...

Страница 19: ...Instruments User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be downloaded here www pce instruments com Specifications are subject to change without no...

Отзывы: