Operating instructions 

If no key is pressed within 15 seconds, the automatic key lock is activated. Press the 

 key 

for three seconds to make operation possible again.  

4.1 

Switch on the device 

The data logger switches on as soon as batteries are inserted into the device. 

4.2 

Switch off the device 

The  data  logger  is  permanently  switched  on  and  switches  off  as  soon  as  the  batteries  are  no 
longer sufficiently charged to ensure proper operation.  

4.3 

Switch on the display 

Press the 

 key for three seconds and the display switches on. 

4.4 

Switch off the display 

Press the 

 key for three seconds and the display switches off.  

 Note

: The display cannot be turned off when it shows REC or MK. 

4.5 

Switching the time / date 

Press the 

 key to switch between date, time and marker view. 

4.6 

Start data recording 

Press the 

 key for three seconds to start data recording. 

4.7 

Stop data recording 

If  the  software  has  been  set  to  stop  recording,  press  the 

 key  for  three  seconds  to  stop 

recording.  
Furthermore, recording stops when the memory is full or the batteries are no longer sufficiently 
charged to ensure proper operation. 

4.8 

Display minimum, maximum and average measured value 

As soon as one or more measured values have been saved to the memory of the data logger, it 

is possible to display the MIN, MAX and average measured values by pressing the 

 key. 

If  no  measured  values  are  recorded,  the 

 key  can  be  used  to  display  the  upper  and  lower 

alarm limits.  

4.9 

Deactivate the audible alarm 

As  soon  as  an  alarm  is  triggered  and  the  meter  beeps,  the  alarm  can  be  acknowledged  by 
pressing one of the two keys.  

 

Содержание PCE-HT 112

Страница 1: ...HT 114 Data Logger User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last cha...

Страница 2: ...g instructions 6 4 1 Switch on the device 6 4 2 Switch off the device 6 4 3 Switch on the display 6 4 4 Switch off the display 6 4 5 Switching the time date 6 4 6 Start data recording 6 4 7 Stop data...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...isplay time 3 Switch display on off show data mark 2 2 Backside 4 External sensor connection 1 5 External sensor connection 2 6 External sensor connection 3 7 External sensor connection 4 8 Reset key...

Страница 5: ...ol 21 MKT mean kinetic temperature1 22 Time unit 23 Upper measured value display 24 House symbol 25 Display symbol 26 Settings symbol 27 MIN MAX average display 28 Warning symbol 29 Buzzer symbol 30 B...

Страница 6: ...5 min 10 min 15 min 20 min 25 min 30 min 1 h or individually adjustable Measuring interval display refresh rate 5 s Alarm adjustable audible alarm Interface USB Power supply 3 x 1 5 V AAA batteries 5...

Страница 7: ...e Measuring interval display refresh rate 5 s Alarm adjustable audible alarm Interface USB Power supply 3 x 1 5 V AAA batteries 5 V USB Battery life approx 1 year without backlight without alarm Opera...

Страница 8: ...4 5 Switching the time date Press the key to switch between date time and marker view 4 6 Start data recording Press the key for three seconds to start data recording 4 7 Stop data recording If the s...

Страница 9: ...ashes or the display shows OFF this indicates that the batteries are low and need to be replaced 6 Warranty You can read our warranty terms in our General Business Terms which you can find here https...

Страница 10: ...e stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co...

Отзывы: