Safety category ratings 

Category rating 

Brief description 

Typical applications 

Cat II 

Single  phase  receptacles 

and connected loads 

• Household appliances, 

  power tools 

• Outlets more than 30 ft 

  (10 m) from a Cat III source 

• Outlets more than 60 ft 

  (20 m) from a Cat IV source 

Cat III 

Three  phase  circuits  and 

single phase lighting circuits 

in commercial buildings 

• Equipment in fixed 

  installations such as 

  3-phase motors, switchgear 

  and distribution panels 

• Lighting circuits in 

  commercial buildings 

• Feeder lines in industrial 

  plants 

• Any device or branch circuit 

  that is close to a Cat III 

  source 

The measurement category (CAT) rating and voltage rating is determined by a combination of the 

meter, test probes and any accessories connected to the meter and test probes. The combination 

rating is the LOWEST of any individual component. 

 

WARNING

: Operation is limited to CAT II applications when the insulated tips are removed from 

one or both test probes. Refer to  the input limits section in this manual for maximum voltage 

ratings. 

 

1 – Insulated tip on 

2 – Insulated tip removed 

 

 

 

Содержание PCE-HDM 7

Страница 1: ...ster PCE HDM 7 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...AC DC voltage measurements 8 5 3 AC current measurements 9 5 4 DC current measurements 9 5 5 Frequency and duty cycle measurements 10 5 6 Resistance measurements 10 5 7 Diode test 11 5 8 Continuity 1...

Страница 3: ...spect the case for visible damage If any damage is visible on the meter or its test leads do not use the device Do not use the meter if it operates incorrectly Protection may be compromised Do not ope...

Страница 4: ...ge with respect to earth ground exceeds the maximum safety rating of the meter This symbol can appear next to another symbol or connection and indicates the user must refer to the manual for important...

Страница 5: ...ear and distribution panels Lighting circuits in commercial buildings Feeder lines in industrial plants Any device or branch circuit that is close to a Cat III source The measurement category CAT rati...

Страница 6: ...V AAA batteries Fuse 10 A 600 V 5 x 20 mm fast blow Operating conditions 0 40 C 32 104 F 70 RH Storage conditions 10 60 C 14 140 F 80 RH Operating altitude Max 2000 m Dimensions 147 x 68 x 50 mm Weigh...

Страница 7: ...solution Accuracy of reading digits AC current 4 000 A 1 mA 2 5 3 10 00 A 10 mA Overload protection 10 A 600 V fuse AC response 50 60 Hz Function Range Resolution Accuracy of reading digits DC current...

Страница 8: ...gits Duty cycle 1 0 99 9 0 1 1 2 2 Input protection 600 V AC RMS or 600 V DC Pulse width 0 1 100 mS Frequency range 5Hz 10kHz Sensitivity 8 V RMS Function Range Resolution Accuracy of reading digits T...

Страница 9: ...wer Off Low battery AUTO Autoranging HOLD Display hold LOZ Low Z impedance MAX MIN Maximum Minimum Bluetooth 3 1 Delivery contents 1 x multimeter PCE HDM 7 1 x test lead 1 x storage bag 1 x K type the...

Страница 10: ...ges Do not connect to circuits that exceed 300 V AC RMS or 300 V DC when the meter is set to Low Z Low Z is used to check for ghost voltage Ghost voltages are present when non powered wires are in clo...

Страница 11: ...wer to the circuit 6 Read the current on the LCD 5 4 DC current measurements WARNINGS Observe all safety precautions when working on live circuits Do not measure current on circuits that exceed 600 V...

Страница 12: ...lead probes to the circuit under test 5 Read the frequency or duty cycle on the LCD 5 6 Resistance measurements WARNING Never test resistance on a live circuit 1 Set the rotary function switch to the...

Страница 13: ...the display Reverse voltage will indicate OL Shorted devices will indicate near 0 and an open device will indicate OL in both polarities 5 8 Continuity WARNING Never test continuity on a live circuit...

Страница 14: ...minute to get a stable reading on large capacitors 5 10 Temperature measurements WARNING Do not touch the temperature probe to live circuits 1 Set the rotary function switch to the F C position 2 Pre...

Страница 15: ...ill update when a lower min occurs 3 Press and hold the MAX MIN button to end MAX MIN mode and return to normal operation NOTE MAX MIN does not work with frequency duty cycle diode test continuity and...

Страница 16: ...o avoid electric shock do not operate meter until the battery fuse cover is securely fastened to the meter Fuse replacement WARNING To avoid electric shock remove the test leads from the meter before...

Страница 17: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 18: ...dustrial needs com info pce italia it www pce instruments com deutsch www pce instruments com english www pce instruments com italiano The Netherlands Chile Hong Kong PCE Brookhuis B V PCE Instruments...

Отзывы: