7.8.3 

Zero calibration 

Prepare a calibration standard for zero calibration. 
Navigate to the menu item "Zero calibration" as described in chapters 7.2 and 7.3 and open it.  
Place the test instrument on the calibration standard as you would for a measurement. The meter 
performs a few measurements and exits the calibration mode. 

7.9 

Error messages  

Display 

Cause 

ERR1  

Probe or base material defective 

ERR2 

Probe or base material defective 

"----" 

Unit not calibrated to the base material 

-OL- 

Coating too thick 

 

Warranty 

You  can  read  our  warranty  terms  in  our  General  Business  Terms  which  you  can  find  here: 

https://www.pce-instruments.com/english/terms

 

Disposal 

For  the  disposal  of  batteries  in  the  EU,  the  2006/66/EC

 

directive  of  the  European  Parliament 

applies. Due to the contained pollutants, batteries must not be disposed of as household waste. 
They must be given to collection points designed for that purpose. 
 
In order to comply with the EU directive 2012/19/EU we take our devices back. We either re-use 
them or give them to a recycling company which disposes of the devices in line with law. 
 
For  countries  outside  the EU,  batteries  and  devices  should  be  disposed  of  in accordance  with 
your local waste regulations. 
 
If you have any questions, please contact PCE Instruments. 
 

 

 
 
 
 

 

Содержание PCE-CT 24FN

Страница 1: ...ng Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last cha...

Страница 2: ...e 2 4 System description 3 5 Preparation 4 6 Battery indicator 4 7 Operation 4 7 1 On off 4 7 2 Menu settings 4 7 3 Menu levels 5 7 4 Measurement 6 7 5 Display indication 7 7 6 Rotate display 10 7 7 M...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...0 5 mm Memory 100 groups of 15 readings each Display 2 25 inch LC display Ambient temperature 0 50 C 32 122 F Power supply batteries 3 x 1 2 V AA Ni MH 800 mAh Power supply mains adaptor Primary 100 2...

Страница 5: ...PCE Instruments 3 4 System description Up Display Down USB socket On Off Menu Battery compartment Back Sensor OK Enter...

Страница 6: ...Menu key When switching on make sure that the probe is at least 10 cm away from the object to be measured To switch off the meter press and hold the On Off Menu key for approx 3 seconds Automatic pow...

Страница 7: ...s Adjustment of the limit values High Limit Low Limit Limit sound On Off 7 3 4 Memory Memory Look back short term memory Look Data Save Data Clear data Browse from the first group data memory sorted b...

Страница 8: ...uccessful measurement is acknowledged by a sound and the measured value is shown on the display The V grooves on the probe help you to align the device on convex measurement objects 7 4 1 Single conti...

Страница 9: ...plays with the Up or Down keys Typical display Header Display mode Battery indicator Upper part Number of current measurements Base material Fe magnetic nFe non magnetic Measuring mode SNG Single meas...

Страница 10: ...Display mode Battery indicator Upper part Number of current measurements Base material Fe magnetic nFe non magnetic Measuring mode SNG Single measurement CTN Continuous measurement Middle part Current...

Страница 11: ...few measurements Max Maximum value of the last few measurements Min Minimum value of the last few measurements High Upper limit value Low Lower limit value Sdev Deviation CV Percentage deviation Sdev...

Страница 12: ...1 Short term memory The short term memory contains the values measured after the last switch on When the meter is switched off the measured values not saved to the long term memory are lost To view sa...

Страница 13: ...ion standard corresponding to the base material of your measurement object for calibration 7 8 1 Base calibration For a base calibration prepare a calibration standard and the calibration foils with i...

Страница 14: ...ur warranty terms in our General Business Terms which you can find here https www pce instruments com english terms 9 Disposal For the disposal of batteries in the EU the 2006 66 EC directive of the E...

Страница 15: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Отзывы: