8.1 

Menu structure  

Menu 

Calibration 

(Calib) 

Zero point calibration 

(Zero Calib) 

Factory calibration 

(Factory calib) 

1-point calibration 

(1 point calib) 

5-point calibration 

(5-point calib) 

Data groups 

(Data Group) 

History 

Selected group  

(Select Grp XXX) 

Delete last value 

(Remove latest) 

Delete group 

(Erase group) 

Clear memory completely 

(Erase all) 

Limit value alarm 

(Limit Alarm) 

Activate alarm 

(alarm on) 

Upper limit value 

(Up limit) 

Lower limit value 

(Low limit) 

Bluetooth 

On, off 

(ON, OFF) 

Unit 

µm, mil 

Device information 

(About) 

Sensor type 

(Type) 

Serial number  

(Serial) 

Hardware version 

(Hardware) 

Software version 

(Software) 

Calibration  

To perform a calibration, the meter has various functions.  

Factory calibration 

Zero point calibration 

One-point calibration 

Five-point calibration 

In order to obtain the most accurate measurement result over the entire measuring range, a five-
point  calibration  is  recommended.  A  calibration  of magnetic  (Fe)  and  non-magnetic substrates 
(nFe) is independent on each other. After each calibration, check the measured values again with 
the references. If the measured values are still not within the accuracies, repeat the calibration if 
necessary. 
 

 

Содержание PCE-CT 21BT

Страница 1: ...Coating Thickness Gauge User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Las...

Страница 2: ...off 4 7 Measurement 4 7 1 Continuous measurement 4 8 Menu 4 8 1 Menu structure 5 9 Calibration 5 9 1 Zero point calibration 6 9 2 One point calibration 6 9 3 Five point calibration 6 10 Data group 7...

Страница 3: ...s The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only...

Страница 4: ...Fe Fe NFe Fe NFe Probe external internal external Measurement range 0 1500 m Resolution 0 1 m within meas range 0 99 9 m 1 m within meas range 100 1500 m Accuracy 1 m 2 of the coating thickness Units...

Страница 5: ...terial m Unit Adjustable units m and mil v Limit value Is displayed when the set limit value is exceeded or fallen below 17 Number of measurements Number of measured values 4 1 Key description Symbol...

Страница 6: ...ccur To carry out further measurements place the sensor on the next measuring spot Important In order to obtain the best results it is important to take measurements on a smooth and non slip surface D...

Страница 7: ...OFF Unit m mil Device information About Sensor type Type Serial number Serial Hardware version Hardware Software version Software 9 Calibration To perform a calibration the meter has various function...

Страница 8: ...asked whether you want to accept the calibration Press the key to save the change To discard the setting press the key 9 3 Five point calibration To perform a five point calibration first go to the ca...

Страница 9: ...e memory 11 Limit value alarm To set limit values first go to the limit alarm menu Under the item Alarm on you can activate the limit alarm function You can set the limits as follows Upper limit value...

Страница 10: ...this is not available the driver may be missing You can find the driver in the program folder under the driver folder If you have a 64 bit system use the installation file CP210xVCPInstaller_x64 If y...

Страница 11: ...le device first download the Coatingmaster app Then switch on the Bluetooth function in the measuring device Now connect the coating thickness gauge via the app To do this select Coating_XXXX in the a...

Страница 12: ...ngs to the app Setting Meaning Measuring sounds During a measurement a sound can be heard Measuring vibration When a measurement is made the vibration alarm is activated Alarm sounds When the limit is...

Страница 13: ...any measurements at the edge Incorrect placement of the probe Always align the probe vertically and quickly with the surface Do not perform a measurement by force The probe must touch the test object...

Страница 14: ...ed pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our dev...

Страница 15: ...tanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 0583 975 114 Tel 0212 471 11 47 Fax 44 0 2380 98703 9 Fax 39 0583 974 824 Faks 0212 705 53 93 info pce instruments co uk...

Отзывы: