6.4 

Configure meter  

To  configure  the  meter,  connect  the  PCE-ADL  11  to  the  PC.  Then  click  on  the  "Setting"  icon. 
Another window opens and the software automatically connects to the meter. 

 

Parameter 

Meaning 

Basic settings 

Model Select 

Instant:  The  meter  starts  the  measurement  directly  after  you 
confirm the configuration via "Setup".  

Important

: A live view is not possible. 

 
Manual: The meter starts the measurement after you press the 
start key on the meter. 

Current Time 

Current  time  of  your  PC.  This  time  is  also  transmitted  to  the 
meter.  

Sample Point 

Number of measuring points to be recorded 

Sample Rate 

Specification of the storage rate 

Recording Time 

This indicates how long the meter measures with the settings 
made until the measurement is finished. 

LED Flash Cycle 

Here you can specify when the status LED should light up 

Alarm settings 

LED flash 

Here you can specify whether the alarm LED flashes when the 
limits are exceeded or not reached. 

Low Alarm 

Here you can enter the limit value for the lower limit. 

High Alarm 

Here you can enter the limit value for the upper limit. 

Unit 

Here you set the unit in which the meter records the data.  

Important: 

The

 

unit  of  the  recorded  data  cannot  be changed 

afterwards. 

More buttons 

Default 

The configuration is reset here. 

Setup 

Here the configuration is transferred to the PCE-ADL 11. 

Attention: 

The

 

already  saved  measurement  data  will  be 

deleted. 

Cancel 

No data is saved and the window closes. 

Содержание ADL 11

Страница 1: ...ter PCE ADL 11 User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...on 3 6 1 Icon description 3 6 2 Graph description 4 6 3 Data download 5 6 4 Configure meter 6 6 5 Zoom into graph 7 6 6 Print graph 7 6 7 Export and import data 7 6 8 Generate CSV file 7 6 9 Further s...

Страница 3: ...ents personnel Never use the instrument when your hands are wet You must not make any technical changes to the device The appliance should only be cleaned with a damp cloth Use only pH neutral cleaner...

Страница 4: ...ttery 1 x user manual 4 Specifications Measurement range 1 2 30 0 m s 4 3 108 0 km h 2 33 58 32 knots 2 69 67 2 mph 236 5906 ft min Resolution 0 01 m s 0 1 km h 0 1 knots 0 1 mph 1 ft min Accuracy m s...

Страница 5: ...form 6 1 Icon description Icon Description Explanation Download The measured values from the PCE ADL 11 can be downloaded here Setting The PCE ADL 11 can be configured here Open Measurement data can...

Страница 6: ...storage interval is displayed here MAX Maximum value The highest measured value in the set storage interval is displayed here MIN Minimum value The lowest measured value in the set storage interval i...

Страница 7: ...ph as a dashed red line 6 3 Data download To download the data from the PCE ADL 11 first connect the meter to your PC Then click on the Download icon Another window appears and the software automatica...

Страница 8: ...ation of the storage rate Recording Time This indicates how long the meter measures with the settings made until the measurement is finished LED Flash Cycle Here you can specify when the status LED sh...

Страница 9: ...nce on View all 6 6 Print graph To print the displayed graph click on Print Now you can print the graph Important The current view is always printed This means that if you have zoomed into the graph o...

Страница 10: ...show or hide the line for the lowest measured values Average trace Here you can show or hide the line for the average values RT trace Show or hide real time line 6 10 Change graph colours To change i...

Страница 11: ...place it The data logger does not lose any saved data when the battery is discharged or replaced However the data storage process is stopped and cannot be restarted until the battery has been replaced...

Страница 12: ...flashes twice every 10 20 or 30 seconds Meter ready for logging Press the yellow key on the back green LED flashes three times Data recording started during the manual start up process Red LED flashe...

Страница 13: ...d pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devi...

Страница 14: ...Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel 44 0 2380 98703 0 Telefono 39 05...

Отзывы: