background image

 

Manual 

 

         

                                                           www.industrial-needs.com 

 

 

5.4 

Switch temperature unit 

The device is set by the manufacturer on °C. To switch to Fahrenheit, press the “°C/F“- button. The 
device will save your settings even, if it is switched off.  

5.5 

Data Hold function 

You can freeze the current measurement values by pressing the “HOLD” key. The display will then 
indicate  “HOLD”.  To  revoke  the  function,  press  the  button  again.  If  the  Data  Hold  function  is 
activated, the functions “REL”, “MIN / MAX” and “°C/F” will be out of order.  

5.6 

Display lights 

The lights of the display can be switched on by pressing the Power-button (

). To switch the lights 

off, press the button again. After 30 seconds the lights are switched off automatically.  

5.7 

Deviation measurements 

If you press the “REL” button, the device will save the current value in its short-time memory and 
indicate in the following the deviation from that value. To exit this function, press the key again. 

5.8 

Data recording 

Note

: The function 

“delete memory”, “data transfer to computer” and “memory settings” are deactivated in 

this mode. 
Set the 

memory interval first (see chapter 5.13 “Change memory interval”). 

To start the recording, press the “REC”- button. The display will then indicate “REC”.  
To stop the recording, press the “REC”- key again.  

5.9 

MAX / MIN function 

By pressing the MIN/MAX button once, you will access the MAX / MIN function. This mode 
indicates the relevant maximum and minimum value at the display 

If the display indicates 

“MAX”, the maximum value will be indicated.  

By  pressing  the 

“MIN/MAX”  key  again,  the  display  switches  to  the  minimum  values.  The 

display will then indicate 

“MIN”. 

By  pressing  the 

“MIN/MAX”-  button  again,  the  symbols  “MIN”  and  “MAX”  will  be  both 

blinking.  This  means  the  minimum  and  maximum  value  will  be  both  saved  on  the  data 
memory, while the display will indicate the current measurement value.  

To exit this function, press the 

“MIN/MAX” button for about 2 seconds. 

5.10  Automatic switch-off 

The automatic switch-off will be pre-set. This means that the device will be automatically shut down, 
if it has been inactive for 30 seconds. To deactivate this function, switch on the device while pressing 
the 

“REL”- button.  

5.11  Indication of the battery state 

A low battery state is indicated by the 

-symbol.  

5.12  Set time and date 

Turn on the device whilst simultaneously pressing the 

“MIN/MAX”-button, in order to access 

the Set-up mode.  

Press  the 

“REL” key,  to access  the settings  of  the  date and  time. Both  the  ciphers  on  the 

right will be blinking. 

Raise  and  decrease  the  values  by  pressing 

“REC” or “°C/F” until the correct month will be 

indicated.  

Confirm your selection with the 

“REL” button. Now the two ciphers on the left will be blinking.  

Содержание PCE-HPT 1

Страница 1: ...n 1 0 16 09 2014 www industrial needs com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign Way Southhampton Hampshire United Kingdom SO31 4RF Phone 44 0 2380 98703 0 Fax 44 0 2380 98703 9 info industrial needs com www industrial needs com ...

Страница 2: ...Switch temperature unit 6 5 5 Data Hold function 6 5 6 Display lights 6 5 7 Deviation measurements 6 5 8 Data recording 6 5 9 MAX MIN function 6 5 10 Automatic switch off 6 5 11 Indication of the battery state 6 5 12 Set time and date 6 5 13 Change the memory interval 7 5 14 Erase memory 7 5 15 Calibrating the device 7 5 16 Return to initial settings 8 6 Data transfer to a computer 8 6 1 Installin...

Страница 3: ...urther evaluations of the captured data Furthermore the measurement results are shown with real time speed The internal clock with time and date facilitates an accurate correlation of the measured data The microprocessor thermometer features an internal data logger with an adjustable measurement interval 1 1 Delivery Content 1 x microprocessor thermometer PCE HPT 1 1 x PT 100 sensor 1 x USB cable ...

Страница 4: ...ted The device cannot be used in explosion hazardous areas The threshold specified in this manual cannot be trespassed under any circumstance Do not use the device if the battery is down e g the display indicates that the battery is low since it might lead to wrong measurement results First change the batteries before operating the device again Please check the measurement device prior to every op...

Страница 5: ...splay lights 4 Button for deviation measurement REL 5 Button for data recording REC 6 Key for MIN MAX function MIN MAX 7 Key for Data Hold function HOLD 8 Switch for temperature unit C F 9 Interface for connection to computer 10 Input for optional adapter 11 Stand 12 Cover of battery compartment 4 1 Pins of connection socket for temperature sensor ...

Страница 6: ...d of the metal tube of the measurement sensor In order to achieve an accurate measurement of internal temperatures insert the sensor head deep into the medium which should equal at least fifteen times the sensor diameter Symbol Explanation The battery state is low No precise operation MIN Indicating minimum value MAX Indicating maximum value HOLD The data HOLD function is activated The function au...

Страница 7: ...s the REC key again 5 9 MAX MIN function By pressing the MIN MAX button once you will access the MAX MIN function This mode indicates the relevant maximum and minimum value at the display If the display indicates MAX the maximum value will be indicated By pressing the MIN MAX key again the display switches to the minimum values The display will then indicate MIN By pressing the MIN MAX button agai...

Страница 8: ...ng Raise or decrease the value by pressing the REC or the C F button until it shows the desired value for the hour 24 hours format Confirm by pressing the REL button Now the two ciphers on the right will be blinking Raise or decrease the indicated value by pressing the REC or the ON OFF button until the correct value for the minutes is indicated Confirm your choice by pressing the REL button Now t...

Страница 9: ...e the function Default factory setting value Confirm with pressing the HOLD key again Note You can cancel the process at any time by pressing the Power button 6 Data transfer to a computer 6 1 Installing the software The enclosed CD will contain the software for the data collection as well as a USD driver for the device The software is compatible with the following system software Windows NT 4 0 N...

Страница 10: ...ce manager under the system settings to see under which COM Port the device is listed e g the example below is the COM4 Port After completing the installation the device can be connected via its USB cable to a computer Start the software and select the correct COM Port in the Drop Down menu ...

Страница 11: ...in minutes and seconds You can save up to 5000 data points In case of transgression the oldest 100 points will be overwritten Option Here you can find the options to alternate the parameters of the graph 6 3 Real time graph Within the graph you can zoom in by pressing the left mouse button and marking an image section and then releasing To revoke the zoom again click on the Undo Zoom button 6 4 Ta...

Страница 12: ... data logger Thus a progress beam will indicate the state of the data transfer After a successful transfer of the data the number of transferred data sets will be indicated at the left side of the display with their parameters time and date of start sampling rate Each data set can be seen in detail as a diagram or a data table by clicking ...

Страница 13: ...oth made of cotton that makes no fluffs If necessary use a mild cleaner Do not use any abrasive detergent or chemical solution 8 Disposal Batteries may not be put in the household waste They have to be given in the set up collection points NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases Please contact PCE Instru...

Отзывы: