©  PCE Instruments 

 

5.2 

Settings 

To  access  the  settings, 
press  the  right  key  in  the 
measurement window. This 
takes  you  directly  to  the 
settings.  
The  left  and  right keys can 
be  used  to  select  between 
the  individual  menu  items 
and  to change  parameters. 
The  enter  key  opens  the 
setting  item  and  the  set 
parameter is accepted. The 
back  key  takes  you  back 
one level.  
 
 
The menu is organised as follows: 

Setting option 

Description

 

Language 

Setting the menu language 
Chinese and English are available 

Unit 

Setting the temperature unit to °C or °F 
Setting the unit for HCHO and TVOC to ppm or mg/m³ 

Datalogger 

Setting the data logger 

Auto-off 

Setting automatic power off 

Alarm 

Setting the alarm limit value 

Brightness 

Setting the display brightness 

Date/Time 

Setting the date and time 

5.2.1 

Setting the language 

To set the language of the meter, go to the menu, to the item 
"Language".  Here,  you  can  change  the  menu  language  to 
Chinese or English.  
 
 
 

5.2.2 

Setting the units 

To  set  the  units,  go  to  the  settings,  to  the  item  "Unit".  From 
there, the unit of temperature can be changed to °C or °F. The 
unit of HCHO and TVOC can be changed to ppm or mg/m³.  

 

 

Содержание PCE-EM 880

Страница 1: ...r Quality Meter User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change...

Страница 2: ...1 2 Specifications 2 3 Delivery scope 2 4 Device description 3 5 Switching the meter on and off 4 5 1 Lowest highest and average reading 4 5 2 Settings 5 6 View measured values 8 7 Exporting the meas...

Страница 3: ...ure Do not expose the device to shocks or strong vibrations The case should only be opened by qualified PCE Instruments personnel Never use the instrument when your hands are wet You must not make any...

Страница 4: ...0 100 RH 0 1 RH 3 5 at 20 80 RH 5 at 0 20 5 at 80 100 Alarm Visual alarm when limit value is exceeded Interface Micro USB Power supply battery 3 7 V 1500 mAh Power supply mains adaptor 5 V DC 1 A Ope...

Страница 5: ...Temperature and humidity sensor 3 LC display 4 Left key interaction with the function shown on the display 5 Right key interaction with the function shown on the display 6 On and off key 7 Enter and r...

Страница 6: ...ain for two seconds The meter switches off 5 1 Lowest highest and average reading To display the lowest the highest and the average measured value press the right key in the measurement window to sele...

Страница 7: ...e and English are available Unit Setting the temperature unit to C or F Setting the unit for HCHO and TVOC to ppm or mg m Datalogger Setting the data logger Auto off Setting automatic power off Alarm...

Страница 8: ...ecording time select Duration in the data logger settings You can select None 1 hour 24 hours or 7 days If None is selected recording will continue until the meter switches off automatically or the ba...

Страница 9: ...s go to the settings and to the item Alarm Here an alarm limit value can be set for each measuring function To change the parameter use the right or left key To move to the next measurement function p...

Страница 10: ...t mode All saved files are now displayed The file name is named and sorted according to the storage date Select the desired file with the left or right key and open it with the enter key Now select th...

Страница 11: ...n at the end of this user manual 9 Disposal For the disposal of batteries in the EU the 2006 66 EC directive of the European Parliament applies Due to the contained pollutants batteries must not be di...

Страница 12: ...Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul United Kingdom SO31 4RF Italia T rkiye Tel...

Отзывы: