background image

 

©  PCE Instruments 

 

 
 
 
 
 

 

 

PCE-DSX 20 Stroboscope 

User Manual 

User manuals in various languages (français, 

italiano, español, português, nederlands, türk, polski, 

русский, 

中文

) can be found by using our 

product search on: www.pce-instruments.com 

Last change: 19 January 2022 

v1.0 

E

nglis

h

 

Содержание PCE-DSX 20

Страница 1: ...Stroboscope User Manual User manuals in various languages fran ais italiano espa ol portugu s nederlands t rk polski can be found by using our product search on www pce instruments com Last change 19...

Страница 2: ...Front and back 3 4 2 Top and bottom 4 5 Operation 4 5 1 Preparation 4 5 2 Set flash frequency 5 5 3 Rotational speed measurement 5 5 4 External input 6 5 5 Synchronised output trigger output 7 5 6 Mo...

Страница 3: ...yes Do not point the stroboscope at other people Light pulses of more than 5 Hz may cause people with photosensitive epilepsy to suffer a seizure Do not touch the lamp with bare hands The case should...

Страница 4: ...PM 0 1 of rdg 2 dgt 9999 RPM 1 RPM 35000 RPM 10 RPM Level ext trigger High 2 5 12 V Low 0 8 V Lamp type Xenon flash Flash response time 10 30 s Colour temperature 6500 K Flash output 8 joules Beam ang...

Страница 5: ...description 4 1 Front and back Screws protective glass Ext trigger input signal output Xenon flash lamp 230 V AC input Internal external selection key MODE key Key X 2 doubling Key Key 2 halving Key...

Страница 6: ...ED Trigger mode LED mSec mode LED Tripod thread 5 Operation 5 1 Preparation Before first use remove the film from the front protective glass and the display Connect the stroboscope to the power supply...

Страница 7: ...s for fine adjustment Per keystroke the last digit of the flash frequency is changed by the value 1 Holding the key changes the tens or hundreds of the flash frequency 5 3 Rotational speed measurement...

Страница 8: ...cope is signalled by flashing of the display and the flash triggering is set 5 4 1 Rotational speed Select speed with the MODE key As soon as an external signal is present the stroboscope flashes in t...

Страница 9: ...e maximum time of use of the stroboscope per measurement should not exceed the following times The pause between measurements should be at least 10 minutes Flash frequency Duration 2000 RPM 4 hours 20...

Страница 10: ...pollutants batteries must not be disposed of as household waste They must be given to collection points designed for that purpose In order to comply with the EU directive 2012 19 EU we take our devic...

Страница 11: ...Unit 11 Southpoint Business Park Via Pesciatina 878 B Interno 6 Halkal Merkez Mah Ensign Way Southampton 55010 Loc Gragnano Pehlivan Sok No 6 C Hampshire Capannori Lucca 34303 K k ekmece stanbul Unite...

Отзывы: