Alarm limits
The alarm limits function is useful, for example, to check during quality control whether the tested
item is working within the specified tolerances. Two limits can be set here. If the measured value
is lower than the set "Lower Limit", this is indicated by the red and green LEDs lighting up. If the
measured value lies between the set "Higher Limit" and the set "Lower Limit", only the green LED
lights up. If the "Higher Limit" is also exceeded, only the red LED lights up.
Note:
This function is only available in the measurement modes RT, PK and Save.
Display
Meaning
H. Limit
Highest limit value clockwise
L. Limit
Lowest limit value clockwise
H. Limit
Highest limit value counterclockwise
L. Limit
Lowest limit value counterclockwise
Now use the arrow keys to select the desired parameter. Press the "Enter" key to make
changes to this value. You can then change the value as desired with the arrow keys. Confirm
the entry with the "Enter" key. Press the "ESC" key to return to measuring mode.
Note:
The second limit value must always be higher than the first set limit value. The set values
are shown above the reading in measuring mode.
8
Communication of interface and output interface
There are two different softwares for the torque meter. Both do not need to be installed. If the
computer does not find the correct drivers, you will find them in the installation folder.
With the Data Software, the memory can be read out and processed. With the Graph Software,
the current measured values can be transferred live to a PC and transmitted both graphically and
in tabular form.