background image

      

VIBRATION

METER

 

Instruction Manual

PCE Americas Inc.

711 Commerce Way 

Suite 8 

Jupiter

FL-33458

USA

From outside US: +1

Tel: (561) 320-9162

Fax: (561) 320-9176

[email protected]

www.pce-instruments.com/english

www.pce-instruments.com

PCE Instruments UK Ltd.

Units 12/13 

Southpoint Business Park 

Ensign way

Hampshire / Southampton

United Kingdom, SO31 4RF

From outside UK: +44

Tel: (0) 2380 98703 0

Fax: (0) 2380 98703 9

    [email protected]

PCE-VD 3

Содержание PCE-VD 3

Страница 1: ...l 561 320 9162 Fax 561 320 9176 info pce americas com www pce instruments com english www pce instruments com PCE Instruments UK Ltd Units 12 13 Southpoint Business Park Ensign way Hampshire Southampt...

Страница 2: ...be performed by qualified personnel Periodically wipe the case with a dry cloth Do not use solvents or eradicator on this instrument Safety symbols Comply with EMC 2 FUNCTIONS DESCRIPTION This datalo...

Страница 3: ...he datalogger will record the time when freefall happens besides normal acceleration data 3 Specification Acceleration Sensor MEMS Semiconductor Acceleration Range 18g Acceleration Resolution 0 00625g...

Страница 4: ...midity 10 C 60 C 10 RH 75 RH Dimension The pedestal 106mm x 56mm x 33 5mm The datalogger 95mm x 28mm x 21mm System Requirement Windows 2000 or Windows XP or Vista Windows 7 8 10 Minimum hardware requi...

Страница 5: ...Button turn on off the Datalogger Direction indication of 3 axis LED FLASH INDICATION LEDs Meaning Action ALM REG O O No LEDs flash No logging started No battery fitted Battery completely discharged F...

Страница 6: ...ttery and download data ALM REG Red and Green single flash every 60 sec Logger memory full Download data 5 OPERATING INSTRUCTIONS 1 Setup the DataLogger by software before use it 2 Under the Manual mo...

Страница 7: ...untill Red LED sequencly flash four times and then logging will stop or connect the datalogger to the host and download the data the datalogger will stop automaticlly 9 DataLogger data can be read tim...

Страница 8: ...l Fix the pedestal with three Screws if screws is permitted in your application this way will be preferable 2 Glue Install Fix the pedestal with glue wait for the pedestal is tightly sticked to the ob...

Страница 9: ...g sampling interval 5 You have to setup the DataLogger by software before use it 6 For the affection of gravity You have to start the logger after fix the logger tightly to the object otherwise the th...

Страница 10: ...rivers you can run the Vibration Datalogger software and communicate with the meter 5 Double click the icon to start the software Click on the icon on the menu bar The Setup window will appear as show...

Страница 11: ...ion Free fall Detection field can be set for detecting Free fall events or not The Manual and Automatic select buttons allows the user to start data logging immediately when exit the Setup window Auto...

Страница 12: ...ct the DATA LOGGER to the USB port B Open the Datalogger software program if it is not still running C Click the Download icon D The Window shown below will appear Click DOWNLOAD to begin transferring...

Страница 13: ...e data from the DATA LOGGER First Setup the sampling rate and sample data points then click RUN to start reading 8 Reading for FFT Analysis Click icon to read real time spectral data for FFT analysis...

Страница 14: ...ency domain graph The software computes real time spectral data using an FFT from 0 to 256 HZ The frequency of the max magnitude will be showed on this panel 9 Please view the Help file for specific a...