1.12
Power connection
A 230V Schuko socket or a 115V NEMA-5-15 socket is required to operate the system. The
soldering system must be fused and connected in accordance with the applicable local
regulations and country-specific installation regulations. The circuit must be protected by a
residual current device (RCD). A fuse holder is located above the cold appliance box, in which
two 10A-carrying 230V fine-wire fuses (5x20mm) must be inserted. In case of a short circuit,
check them and replace them if necessary. If you use the vapor phase soldering system in
230V operation, please set the voltage selector switch to 230V. In case of 115V supply, set
the voltage selector switch to 115V.
Do not adjust this switch while mains voltage is
applied!
Figure 3: Voltage selector switch