Model Y685A19

 

Mechanical Switch with Remote Reset solenoid and 24VDC  powered.

 

Installation and Operating Manual

 

For assistance with the operation of this product,

contact the PCB Piezotronics, Inc.

 

Toll-free: 800-959-4464

24-hour SensorLine: 716-684-0001

Fax: 716-684-3823

E-mail: [email protected]

Web: www.imi-sensors.com

Содержание IMI SENSORS Y685A19

Страница 1: ...noid and 24VDC powered Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 800 959 4464 24 hour SensorLine 716 684 0001 Fax 7...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...N MONITORING Model 685A09 685A19 29 39 Mechanical Vibration Switch Operating Guide 3425 Walden Avenue Depew New York 14043 2495 Phone 716 684 0003 Fax 716 684 3823 Toll Free Line 1 800 959 4IMI MANUAL...

Страница 7: ...NE CONDITION MONITORING Table of Contents Introduction Page 3 General Features Warning Installation Page 4 Internal Switches Page 4 Remote Reset and Power On Delay Page 5 6 Setting Up The Switch Page...

Страница 8: ...enclosure Remote Reset 685A19 24VDC Remote Reset 685A29 120VAC Remote Reset 685A39 240VAC Remote Reset Top cover is secured with socket head cap screws for easy access to wiring terminals WARNING AC a...

Страница 9: ...tches in the next section for electrical terminal locations and for typical wiring DO NOT EXCEED VOLTAGE OR CURRENT RATINGS OF THE CONTACTS Follow appropriate electrical codes methods when making elec...

Страница 10: ...t least 2A of current Upon power up the unit will need the 2A to energize the remote reset coil Depending on ambient temperature this will decrease to approximately 0 4A after 5 10 seconds After that...

Страница 11: ...inutes 2 Minutes NOTE If using the solenoid for a power on delay do not exceed the on times listed If the on time exceeds 4 minutes and or the off time is shortened before energizing the solenoid agai...

Страница 12: ...e Depress the reset button and restart the machine Repeat this process until the unit does not trip on start up 5 If the instrument does NOT trip on start up stop the machine Turn the sensitivity adju...

Страница 13: ...PAGE 8 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Typical Installation Locations Cooling Tower Fan and Motor Reciprocating Compressor...

Страница 14: ...PAGE 9 SENSORS AND INSTRUMENTATION FOR MACHINE CONDITION MONITORING Vibratory Screens...

Страница 15: ...t HousingMaterial Aluminum Alloy Aluminum Alloy Electrical Connector Screw Terminals Screw Terminals Screw Terminal Wire Size 24 14 AWG 0 2 2 5 mm Cable Input 3 4 14 NPT 3 4 14 NPT MountingHole Size 0...

Страница 16: ...ECHANICAL VIBRATION SWITCH 685A09 A19 A29 A39 DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 KRM 1 4 17 JDM 1 4 17 JDB 1 4 17 56470 PCB Piezotronics Inc claims proprietary rights in the information dis...

Отзывы: