Model Number

130A 25

ICP® ELECTRET ARRAY MICROPHONE

Revision: NR
ECN #: 50628

P erfo rm an ce

EN G L ISH

SI

Nominal Microphone Diameter

1/4"

1/4"

Frequency Response Characteristic(at 0°
incidence)

Free-Field

Free-Field

Frequency Response(± 2 dB)

20 to 10,000 Hz

20 to 10,000 Hz

Frequency Response

(± 3 dB)

10 to 16,000 Hz

10 to 16,000 Hz

Frequency Response

(± 4 dB)

10 to 20,000 Hz

10 to 20,000 Hz

Phase Match(100 Hz to 3 kHz)

± 3 °

± 3 °

[1]

Phase Match

(50 Hz to 5 kHz)

± 5 °

± 5 °

[1]

Phase Match

(5 kHz to 10 kHz)

± 10 °

± 10 °

[1]

Sensitivity

45 mV/Pa

45 mV/Pa

Sensitivity

(+/- 3)(@ 250 Hz)

-26.9 dB re 1 V/Pa

-26.9 dB re 1 V/Pa

Inherent Noise(Linear)

29 dB re 20 µPa

29 dB re 20 µPa

[1]

Inherent Noise

(A Weighted)

< 26 dB(A) re 20 µPa

< 26 dB(A) re 20 µPa

Inherent Noise

(A Weighted)

24 dB(A) re 20 µPa

24 dB(A) re 20 µPa

[1]

Dynamic Range(3% Distortion Limit)

122 dB re 20 µPa

122 dB re 20 µPa

[1]

TEDS Compliant

Yes

Yes

[2]

En viro n m en tal

Temperature Range(Operating)

+14 to +122 °F

-10 to +50 °C

Temperature Effect on Output(-10 to +50
°C)

0.7 dB

0.7 dB

[1]

Electrical

Excitation Voltage

18 to 30 VDC

18 to 30 VDC

Constant Current Excitation

2 to 20 mA

2 to 20 mA

Output Bias Voltage

5.5 to 14 VDC

5.5 to 14 VDC

Output Impedance

< 150 Ohm

< 150 Ohm

P h ysical

Housing Material

Stainless Steel

Stainless Steel

Electrical Connector(Output)

10-32

10-32

Size (Diameter x Length)(overall)

0.28 in x 1.35 in

7.0 mm x 34.4 mm

Weight

0.19 oz

5.3 gm

[1]

[3]

All specifications are at room temperature unless otherwise specified.
In the interest of constant product improvement, we reserve the right to change specifications without notice.

ICP

®

 is a registered trademark of PCB Piezotronics, Inc.

OP TION A L  VERSION S

Optional versions have identical specifications and accessories as listed for the standard model except

where noted below. More than one option may be used.

N OTES:

[1]Typical.
[2]TEDS Capable Digital Communication, compliant with IEEE 1451.4
[3]See PCB Declaration of Conformance PS023 for details.

Date: 03/24/2020

Date: 03/24/2020

Date: 03/24/2020

Date: 03/24/2020

72403

Entered: LK

Engineer: MJN

Sales: MV

Approved: NJF

Spec Number:

3425 Walden Avenue, Depew, NY 14043

Phone: 716-684-0001
Fax: 716-684-0987
E-Mail: [email protected]

Содержание 130A25

Страница 1: ...EAMPLIFIER 10 32 CONNECTOR TEDS Installation and Operating Manual For assistance with the operation of this product contact the PCB Piezotronics Inc Toll free 716 684 0001 24 hour SensorLine 716 684 0...

Страница 2: ...alized tests including sensitivity at elevated or cryogenic temperatures phase response extended high or low frequency response extended range leak testing hydrostatic pressure testing and others For...

Страница 3: ...tion on particular operating steps The following symbols may be found on the equipment described in this manual This symbol on the unit indicates that high voltage may be present Use standard safety p...

Страница 4: ...China RoHS 2 Disclosure Table Pb Hg Cd Cr VI PBB PBDE O O O O O O PCB X O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O X O O O O O O O O O X O O O O O O O O O O O X O O O O...

Страница 5: ...O Wires O O O O O O Cables X O O O O O Plastic O O O O O O Solder X O O O O O Copper Alloy Brass X O O O O O This table is prepared in accordance with the provisions of SJ T 11364 O Indicates that sai...

Страница 6: ...oustic mode analysis near field acoustic holography or sound intensity measurments To ensure the best performance from your 130 series microphone follow the installation and operating procedures in th...

Страница 7: ...g distances with negligible signal loss 3 0 Powering All ICP powered microphones require constant current excitation for proper operation For this reason use only PCB constant current signal condition...

Страница 8: ...he end of the housing Sharp edged tools can be used to aid in cover removal but it is important to keep the tool at a shallow angle DO NOT make contact with the microphone s delicate diaphragm right h...

Страница 9: ...ce with ISO 9001 ISO 10012 1 and ANSI NCSL Z540 3 4 Due to state of the art limitations 4 1 calibration ratios are not possible on pressure measurement standards microphones and acoustic calibrators C...

Страница 10: ...e with ISO 9001 ISO 10012 1 and ANSI NCSL Z540 3 4 Due to state of the art limitations 4 1 calibration ratios are not possible on pressure measurement standards microphones and acoustic calibrators Ca...

Страница 11: ...ibration is performed in compliance with ISO 9001 ISO 10012 1 and ANSI NCSL Z540 3 4 Due to state of the art limitations 4 1 calibration ratios are not possible on pressure measurement standards micro...

Страница 12: ...ver the microphone output may be affected by harsh environments such as moisture dirt mechanical shock or other unusual conditions This may manifest itself in a number of ways ranging from a loss in f...

Страница 13: ...828 8840 ISO 9001 CERTIFIED AS9100 CERTIFIED In the interest of constant product improvement specifications are subject to change without notice Copyright PCB Group Inc 2016 PCB and ICP are registered...

Страница 14: ...7 dB 1 Electrical Excitation Voltage 18 to30 VDC 18 to30 VDC Constant Current Excitation 2 to20 mA 2 to20 mA Output Bias Voltage 5 5 to14 VDC 5 5 to14 VDC Output Impedance 150 Ohm 150 Ohm Physical Ho...

Страница 15: ...003 005 FILLETS AND RADII 0 07 0 13 OUTLINE DRAWING 72402 1 OF 1 5X MODEL 130A25 ICP MICROPHONE DECIMALS XX 03 XXX 010 DECIMALS X 0 8 XX 0 25 JJF 3 23 20 JJF 3 23 20 MJN 3 23 20 72402 PCB Piezotronic...

Отзывы: