Paxton PROXIMITY architectural reader Скачать руководство пользователя страница 1

Ins-30040 PROXIMITY architectural reader 

26/01/2010

Technical Support

Technical help is available:     Monday - Friday from 07:00 - 19:00 (GMT)

                                 Saturday from 09:00 - 13:00 (GMT)

01273 811011

[email protected]

Fitting

The reader insert is held against the backplate by an outer 

decorative bezel secured with 4 small screws.  Remove these 

screws to release the bezel and refit after adding the insert.

If you have made an insert of less than 5 mm thick, this can 

still be fitted by using the 3 nylon screws supplied in the 

fitting kit to hold the insert against the bezel. (see diagram)

To remove the reader, insert the 

tool provided into the cut out 

on the underside of the reader.  

Push up the clip and pull the 

reader from the backbox.

Reader insert

Removing the reader 

Ensure that the backbox is mounted vertically and is 

square with the wall surface.

Care must be taken when doing this, as no further ‘twist’ 

adjustment is possible within the reader mountings.

Line up the two locating pins on the top of the 

reader with the top plate inside the backbox. 

Once located, the reader can be clipped into the 

box at the bottom using the clip feature.

Check that the reader is located against the 

surface of the wall. If there is a gap between 

the reader and the wall, or if the reader will 

not successfully clip into the box, remove the 

reader and adjust the mounting plates inside the 

backbox using a 3 mm Allen key.

Mounting the reader

Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/