Paxton BLU Expansion Controller Скачать руководство пользователя страница 6

6

V

2

1

V

0

V

2

1

V

0

V

2

1

V

0

U

S

P

V

0

INPUT

AC  100-240V

                      50 / 60 Hz

                      1.2A

OUTPUT      DC  13.8V        2A

V

2

1

V

0

V

2

1

V

0

V

2

1

V

0

U

S

P

V

0

INPUT

AC  100-240V

                      50 / 60 Hz

                      1.2A

OUTPUT      DC  13.8V        2A

V

2

1

V

0

V

2

1

V

0

V

2

1

V

0

U

S

P

V

0

INPUT

AC  100-240V

                      50 / 60 Hz

                      1.2A

OUTPUT      DC  13.8V        2A

V

2

1

V

0

V

2

1

V

0

V

2

1

V

0

U

S

P

V

0

INPUT

AC  100-240V

                      50 / 60 Hz

                      1.2A

OUTPUT      DC  13.8V        2A

Connecting to Paxton BLU Expansion Controllers via RS485 Data Connection

You can connect up to a maximum of 24 Paxton BLU Expansion units to one Master unit (for a total of 50 doors). The Master unit handles all 
communication with the outside world. Mulitple Master units can be installed on a single site. These can be logically grouped in the software to 
appear as a single site. 

The Master unit connects to Expansion units through a dedicated RS485 connection. Each cable section, between Master and Expansion and 
between Expansion and Expansion has its own section of cable carrying the half-duplex RS485 communication between units. Termination of 
the 485 data bus is done automatically by each Master and Expansion controller, eliminating the need for field installed bus termination resistors.

Reader and Data Cable – Shield Drain Connections

Data cable MUST have the spare wires and shield drains connected to the 0V terminals 
throughout the bus or communication errors may occur. Reader and keypad ‘drain wires’, where 
provided, should be connected to the Black (0V) terminal.

MASTER UNIT

MASTER UNIT RS485

MIDDLE EXPANSION RS485

END EXPANSION RS485

Shield drain

Shield drain

Shield drain

RS485

DOOR 1

DOOR 3

DOOR 49

DOOR 2

DOOR 4

DOOR 50

RS485

EXPANSION UNIT

EXPANSION UNIT

GSM

ETHERNET

Содержание BLU Expansion Controller

Страница 1: ...Expansion Controller Installation Guide Ins 60006 GD US ...

Страница 2: ...s such debris may create a fire or shock hazard Unpack the unit with care and inspect for transit damage If damage is suspected the unit must not be used or tested but you should immediately contact Paxton technical support to assist in troubleshooting or to provide return authorization INSTALLATION Only qualified and trained personnel familiar with this type of product and who fully understand th...

Страница 3: ...his housing should be fixed to the surface with suitable fasteners screws and wall plugs are provided for this in the fitting kit Also provided are cable ties to secure the cabling and a smaller securing screw for the lid ...

Страница 4: ...maglock wire 12V 24V to the N C terminal instead of N O Repeat the Exit button connections for door 2 if a second door is required Diode Door 1 Reader Keypad Door 2 Reader Keypad To Expansion controller Use shielded data cable Belden 9841 single pair or technical equivalent From Master controller or previous expansion Tamper switch cabinet Expansion controller ...

Страница 5: ... fault reset failed contact Paxton Inc Ok 2 flashes Error 2 Not currently used Ok 3 flashes Error 3 485 IN not connected upstream Expansion or Expansion Ok 4 flashes Error 4 Not currently used Ok 5 flashes Error 5 Not currently used Ok 6 flashes Error 6 Not currently used Connecting the Paxton BLU Expansion Controller Wire the components to the Paxton BLU Expansion Controller as shown on page 4 Po...

Страница 6: ...pear as a single site The Master unit connects to Expansion units through a dedicated RS485 connection Each cable section between Master and Expansion and between Expansion and Expansion has its own section of cable carrying the half duplex RS485 communication between units Termination of the 485 data bus is done automatically by each Master and Expansion controller eliminating the need for field ...

Страница 7: ...ttach the interface adapter Please do so carefully and be sure that the PCB is fully secured to the bracket upon completion of the firmware update process CAUTION Make sure the adapter is plugged into both rows of the header on the PCB before you proceed see image below for proper placement and connection Power up the controller with the installer tool adapter installed Note your PC or laptop may ...

Страница 8: ...firmware update will take a minute once the green bar has progressed to fill the space the update is complete You can check the version of firmware installed using the View Device Detail option described in the previous section Tip It is useful to know which version of firmware is installed whenever you contact Technical Support Tip Remember to always download the latest version of the installer t...

Страница 9: ...ture Battery limits 0 C 32 F 55 C 131 F Weatherproof No Communication RS485 network speed 115 2 kbits sec RS485 Dataline 3280 84 ft 100m between controllers Features Number of Cards 100 000 Number of PINs 100 000 Access levels per customer 1000 Time zones 512 Door open time 1 sec 99 999 sec Data lines per system unlimited Doors per controller 2 Reader ports per controller 2 Readers Keypads per por...

Страница 10: ...10 Events stored in controller with no server connection 200 000 Dimensions Controller 4 1 64 inch W 4 3 4 inch H 1 inch D Cabinet 9 1 4 inch W 12 1 2 inch H 3 1 8 inch D ...

Страница 11: ...11 ...

Страница 12: ...18 08 2017 Paxton Ltd Ins 60006 GD US Managed access controller Expansion 837 520 US 838 621 US 1 0 3 Made in the UK ...

Отзывы: