background image

FOR USE IN RESIDENTIAL OR 

MANUFACTURED HOME APPLICATIONS.

Thank you for purchasing this Pavilion Tankless Gas Water 

Heater. 

Before using:
•  Read this manual completely for operation instructions.

•  To be covered by the Pavilion Limited Warranty service, see 

the warranty registration information (See page 23), and 

then visit the Pavilion web site (https://www.peerlessboilers.

com/).

•  Keep this manual because the warranty registration 

information is included (See page 23).

Installation must conform with local codes, or in the absence of 

local codes, the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 

- latest edition and/or the Natural Gas and Propane Installation 

Code CSA B149.1 - latest edition.
When applicable, installation must conform with the 

Manufactured Home Construction and Safety Standard, Title 

24 CFR, Part 3280 or the Canadian Standard CAN/CSA-Z240 MH 

Mobile Homes, Series M86.
PB Heat reserves the right to discontinue, or change at any 

time, the designs and/or specifications of its products without 

notice.

•  Do not store or use 

gasoline or other 

flammable vapors and 

liquids in the vicinity 

of this or any other 

appliance.

• WHAT TO DO IF YOU SMELL GAS

  - Do not try to light any appliance.

  -  Do not touch any electrical switch; do not use any 

phone in your building.

  -  Immediately call your gas supplier from a 

neighbor’s phone. Follow the gas supplier’s 

instructions.

  -  If you cannot reach your gas supplier, call the fire 

department.

•  Installation and service 

must be performed by 

a qualified installer, 

service agency or the 

gas supplier.

If the information in this manual is not followed exactly, a fire or explosion may result 

causing property damage, personal injury or death.

WARNING

Low NOx Approved by SCAQMD

14 ng/J or 20 ppm

(Natural Gas Only)

SBB819F-2

Rev. 12/19

Owner’s Guide

CONDENSING RECIRCULATING TANKLESS GAS WATER HEATER

Model : PR199DV 

(GQ-C3260WXQ-FF PB US)

PB HEAT, LLC

Содержание GQ-C3260WXQ-FF PB US

Страница 1: ...CAN CSA Z240 MH Mobile Homes Series M86 PB Heat reserves the right to discontinue or change at any time the designs and or specifications of its products without notice Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone...

Страница 2: ...ducts 1 Far away from the Water Heater 2 In approved containers 3 Tightly closed 4 Out of children s reach Vapors 1 Cannot be seen 2 Vapors are heavier than air 3 Go a long way on the floor 4 Can be carried from other rooms to the main burner by air currents After the Water Heater has been out of use for a long time make sure that you fill the condensate trap with water This is to prevent dangerou...

Страница 3: ...echnician replace it Do not plug or remove the valve Failure to follow these instructions can result in fire or explosion and personal injury or death Check the temperature of the running hot water before entering the shower Check the temperature before stepping into the bathtub WARNING To prevent burns or scalding turn off the button and wait until the appliance cools before performing maintenanc...

Страница 4: ...t and or cause incomplete combustion damage to the electrical components or electric leakage Do not turn off the Water Heater while someone is bathing Do not cover the Water Heater and the exhaust vent terminal store trash or debris near it or in any way block the flow of fresh air to the appliance Do not touch the exhaust vent pipe and exhaust vent terminal during or immediately after operation o...

Страница 5: ...ectrical components For single handle fixtures you d turn the handle to the left This appliance is configured for installations up to 2 000 ft above sea level without changes For installations above 2 000 ft above sea levels contact Pavilion customer center for guidance NOTICE Do not disassemble the Remote Controller Do not use chlorine based acidic alkaline detergents organic solvents such as ben...

Страница 6: ...ation 9 Using the Water Heater 10 Setting Hot Water Temperature 10 Customizable Settings 11 Limiting the Maximum Output Temperature 11 Muting the Remote Controller 12 Flow Meter Alarm 12 Stopping Recirculation Operation 12 Preventing Damage from Freezing 13 Regular Maintenance 15 Troubleshooting 17 Follow up Service 20 Specifications 22 Warranty 23 Contents ...

Страница 7: ...ged from the condensate drain pipe approximately 2 gallons h 7 5 L h maximum It is not a water leak Do not plug or block the drain line as it must always be allowed to freely flow Note The condensate discharged is acidic with a pH level of approximately 2 3 A condensate neutralizer may be required by local code prior to disposal General Parts During combustion white steam may often be seen This is...

Страница 8: ...the Installation Manual 1 POWER Button Indicator For turning the Water Heater ON OFF 2 SETTINGS Button For setting the flow meter alarm and other settings 3 Buttons For setting the hot water temperature the flow meter alarm and other settings 4 PRIORITY Indicator When this indicator is displayed the hot water temperature can be set 5 BURNER ON Indicator When burning the indicator is displayed 6 Te...

Страница 9: ... you leave the button on and hot water is not used for more than 3 days the stored recirculation operation will be reset To avoid this turn the button off the Remote Controller when hot water will not be used for prolonged times i e vacation Auto Recirculation Mode doesn t operate when using On Demand Mode You can manually stop the Recirculation operation See page 12 Before the first use do the fo...

Страница 10: ...Temperature e g 110 F e g 105 F 2 Set the temperature using the buttons 1 The button is ON Operation The POWER indicator is displayed The previously set hot water supply temperature is shown Setting Hot Water Temperature NOTE Hot water temperatures shown are approximate and may differ from the actual temperature at the fixture depending on external factors such as the season and length of piping i...

Страница 11: ...et using the Remote Controller See page 11 60 C 140 F Display when high temperature is set e g 125 F NOTE Consult local codes for minimum operating temperatures It is recommended that water temperature is set as low as possible to prevent scale build up in the Heat Exchanger Limiting the Maximum Output Temperature The maximum output temperature can be limited to prevent discharging hot water at to...

Страница 12: ... cannot be muted The high temperature warning tone when setting the unit to 125 F 55 C 131 F or higher will not emit a sound when muted 4 Turn on hot water 5 Turn off the hot water when the alarm sounds to prevent overfilling The alarm will not sound if it is set for 990 gal 990 L The level can only be adjusted while the flow meter setting is blinking After 10 seconds the Remote Controller will ag...

Страница 13: ...ing If there is still a risk that the Water Heater will freeze drain the Water Heater as shown on the next page 1 Turn off the button 2 Close the gas supply valve 3 Open a hot water fixture faucet and keep a small stream of hot water running 0 1 gallon 400 mL minute or about 0 2 in 4 mm thick If there is a mixing valve set it to the highest level 0 2 in 4 mm thick Hot water fixture faucet NOTE If ...

Страница 14: ...of isolation valve on cold water side 9 Open other drain plugs C D E F and wait until finish draining water b a 9 When the water is completely drained reattach all drain plugs and close the hot water fixtures faucets A B C E F D 5 Fully open all hot water fixtures faucets 6 Open drain plug A on the hot water side Or open the port a and small valve b of isolation valve on hot water side 7 Open drai...

Страница 15: ...as been out of use for a long time make sure that you fill the condensate trap with water This is to prevent dangerous exhaust gases from entering the building Failure to fill the condensate trap could result in severe personal injury or death By performing step 4 as described below the condensate trap will automatically fill itself with water DANGER Do not touch the power cord with wet hands WARN...

Страница 16: ...e to clean the Remote Controller discoloration deformation scratches or cracks may occur The Remote Controller is water resistant but not water proof Keep it as dry as possible Water Drain Valve with Water Filter If the water drain valve with water filter is covered with debris the hot water may not run smoothly or the Water Heater may put out cold water Check and clean the filter as explained bel...

Страница 17: ...or less Residual chlorine 4 mg L or less Source EPA National Secondary Drinking Water Regulations 40 CFR Part 143 3 Maximum limit suggested approved by the manufacturer Water Quality and Maintenance Regular Maintenance Troubleshooting Initial Operation Temperature Troubleshooting The Water Heater does not attempt to ignite when water is running Check for reversed plumbing or crossed pipes Check th...

Страница 18: ...ations and other plumbing conditions can cause the temperature and pressure at a fixture to be unstable but it should stabilize after a short time There are some types of hot water taps that discharges large volumes of hot water at first but stabilize after time To keep the temperature stable the Water Heater limits the amount of water that can flow through it to a small amount initially but the a...

Страница 19: ... is no hot water being used The Water Heater operates automatically to recirculate water prevent freezing or prevent stagnant water It is not abnormal Sounds Frequent water discharge from the condensate drain pipe Condensation forms inside the Water Heater during operation and is discharged from the condensate drain pipe Check for an Error Code on the Remote Controller When a failure occurs inform...

Страница 20: ...ee the warranty Details of problem Blinking error codes etc in much detail as possible Your name address and telephone number Desired date of visit First follow the instructions in the troubleshooting section See page 17 20 If the error is not corrected contact Pavilion Customer Center at 1 855 443 8468 NOTE A request for service may be rejected if the Water Heater is installed in a location where...

Страница 21: ... proper gas type 4 The following pressure value are verified by the installer The inlet gas pressure value at the gas supply inlet fitting The offset pressure value at the gas valve 5 Proper adjustments will be made to ensure safe and efficient operation 6 Once this is completed a final gas leak check will be performed to confirm that all parts have been securely installed NOTE Make sure that all ...

Страница 22: ...s Inlet NPT 3 4 in Condensate Drain NPT 1 2 in Power Supply Supply 120 VAC 60 Hz Consumption NG 218 W LP 202 W Freeze Prevention 114 W Maximum Current 4 Amps Materials Casing Front Cover Hot dipped zinc aluminum magnesium alloy coated steel w Polyester Coating Casing Zincified Steel Plate Polyester Coating Flue Collar PP Primary Heat Exchanger Stainless Steel Sheeting Stainless Steel Tubing Second...

Страница 23: ... or poorly treated well water or water with high PH levels or hardness levels in excess of 12 grains per gallon 200mg L please refer to the Water Quality section of the Owner s Guide for details damage caused during shipment allowed to freeze subjected to flood conditions operated with water conditions and or fuels or additives which cause unusual deposits or corrosion in or on the heat exchanger ...

Страница 24: ... NOT EXTEND TO ANYONE EXCEPT THE FIRST OWNER AT RETAIL AND ONLY WHEN THE PRODUCT IS IN THE ORIGINAL INSTALLATION SITE THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED WITH RESPECT TO ALL OWNERS FAILURE TO FULLY REGISTER THE PRODUCT WITH PB HEAT SHALL HAVE NO EFFECT ON THE DISCLAIMER...

Отзывы: