Water Level Adjustment
Water Level Adjustment
Water level can be adjusted means of height adjustment of the floater.
For this purpose lift up the locking screw (1).
Open the cover (2). Loose the hexagon nut (102.0621) (3), adjust the floater at desired height (3) and
tighten the nut on again. Close the cover. Click into place the locking screw.
Take care of the following:
Float valve has to be placed that way that it is situated in a 90° angle to the valve lever (102.0393).
Water pressure max. 5 bar (73 psi)
Height adjustment
Increased frost protection of the valve
For extremely cold areas subsequent installation of a valve heating model 527 (131.0527, 24 V, 7 W) is recommended for increased frost protection.
Max. cable lengths
Section
e.g.: Type NYY
till
100 Watt
till
200 Watt
till
300 Watt
till
400 Watt
2,5 mm²
83 m
42 m
28 m
21 m
4,0 mm²
132 m
66 m
44 m
33 m
6,0 mm²
200 m
100 m
66 m
50 m
Guidelines. Please note cable data sheets and local standards
All installation, maintenance and inspection works must be carried out by an authorised and qualified specialist. Local norms must be respected.
Attention!
The drinking bowl must
not be run without
water
if the heating is activated!
131.0527
131.0527
2
3
1
102.0621
102.0393