background image

End User License Agreement

55

SmartNode 4970A User Manual 

G

 

• End user license agreement

End User License Agreement

By opening this package, operating the Designated Equipment or downloading the Program(s) electronically, 
the End User agrees to the following conditions:

1. Definitions

A)

“Effective Date” shall mean the earliest date of purchase or download of a product containing the Patton 

Electronics Company Program(s) or the Program(s) themselves.

B)

“Program(s)” shall mean all software, software documentation, source code, object code, or executable 

code.

C)

“End User” shall mean the person or organization which has valid title to the Designated Equipment.

D)

“Designated Equipment” shall mean the hardware on which the Program(s) have been designed and 

provided to operate by the End User.

2. Title

Title to the Program(s), all copies of the Program(s), all patent rights, copyrights, trade secrets and proprietary 
information in the Program(s), worldwide, remains with Patton Electronics Company or its licensors.

Patton does not convey any intellectual property title or rights in the Licensed Products to Licensee. All 
Licensed Products furnished by Patton, and all copies thereof, and compilations, programmatic extension, and 
all Patches, Updates, Upgrades and Platform Releases, are and shall remain the property of Patton or Patton’s 
licensors, as applicable. Further, the Licensed Products provided under this Agreement are not custom software 
but are standard commercial software. Except for the license use rights otherwise expressly provided in this 
Agreement, no right, title or interest in Patton Licensed Products is granted hereunder. Licensee shall not use 
any proprietary information of Patton to create any computer software program or user documentation, which 
is substantially similar to the Licensed Products.

3. Term

The term of this Agreement is from the Effective Date until title of the Designated Equipment is transferred by 
End User or unless the license is terminated earlier as defined in section 

“6. Termination”

 on page 56.

4. Grant of License

A)

During the term of this Agreement, Patton Electronics Company grants a personal, non-transferable, 

non-assignable and non-exclusive license to the End User to use the Program(s) only with the Desig-
nated Equipment at a site owned or leased by the End User.

B)

The End User may copy licensed Program(s) as necessary for backup purposes only for use with the Des-

ignated Equipment that was first purchased or used or its temporary or permanent replacement.

C)

The End User is prohibited from disassembling; decompiling, reverse-engineering or otherwise attempt-

ing to discover or disclose the Program(s), source code, methods or concepts embodied in the Pro-
gram(s) or having the same done by another party.

D)

Should End User transfer title of the Designated Equipment to a third party after entering into this 

license agreement, End User is obligated to inform the third party in writing that a separate End User 
License Agreement from Patton Electronics Company is required to operate the Designated Equipment.

Содержание SmartNode 4970A Series

Страница 1: ...Office 1 301 975 1000 Technical Support 1 301 975 1007 E mail support patton com WWW www patton com Part Number 07MSN4970A Rev B Revised August 20 2018 Important This is a Class A device and is not i...

Страница 2: ...s furnished under a license and may be used or copied only in accordance with the terms of such license For information about the license see Appendix G End user license agreement on page 54 or go to...

Страница 3: ...8 3 SmartNode installation 20 4 Initial configuration 25 5 Contacting Patton for assistance 30 A Compliance information 33 B Specifications 36 C Cabling 40 D Port pin outs 46 E SmartNode 4970A factory...

Страница 4: ...SmartNode installation 20 Planning the installation 21 Site log 21 Network information 21 Network Diagram 21 IP related information 21 Software tools 22 AC Power Mains 22 Location and mounting requir...

Страница 5: ...r credit 32 Return for credit policy 32 RMA numbers 32 Shipping instructions 32 A Compliance information 33 Compliance 34 EMC 34 Safety 34 PSTN Regulatory 34 FCC Part 68 ACTA Statement 34 Industry Can...

Страница 6: ...setting the SmartNode device when it is operating and the Power LED is lit 52 Resetting the SmartNode device when it is initially powered off 53 G End user license agreement 54 End User License Agreem...

Страница 7: ...rk 29 8 Connecting a serial terminal 41 9 Typical Ethernet straight through cable diagram for 10 100Base T 42 10 Typical Ethernet straight through cable diagram for 1000Base T 43 11 Connecting an E1 P...

Страница 8: ...ple site log entries 21 5 Factory Default IP Address and Network Mask Configuration 27 6 Ethernet RJ45 socket 10 100Base T 47 7 Ethernet RJ45 socket 1000Base T 47 8 PRI RJ 45 socket 48 9 Results from...

Страница 9: ...ontains compliance information for the router Appendix B starting on page 36 contains specifications for the routers Appendix C starting on page 40 provides cable recommendations Appendix D starting o...

Страница 10: ...supply when the power cord is connected The mains outlet used to power the SmartNode device shall be within 10 feet 3 meters of the device be easily accessible and protected by a circuit breaker For A...

Страница 11: ...r mit Wechselstrom betriebene Ger te die 3 polige Netzstecker haben L1 L2 u GND oder Phase Neutralleiter u Schutzleiter muss die Steckdose geerdet sein F r mit Gleichstrom betriebene Ger te muss sich...

Страница 12: ...ng Garamond blue type Indicates a cross reference hyperlink that points to a figure graphic table or section heading Clicking on the hyperlink jumps you to the reference When you have finished reviewi...

Страница 13: ...13 Chapter 1 General information Chapter contents SmartNode 4970A overview 14 SN4970A model codes 14 SmartNode 4970A rear panel 15 SmartNode 4970A front panel 16...

Страница 14: ...ts and one Gigabit Ethernet port Proven Interoperability Interoperable with all the major brand softswitches and IP PBXs Management Provisioning Web based management SNMP v1 v3 TR 069 Http Https Comma...

Страница 15: ...ng E1 2 048Mbps or T1 1 533 Mbps PRI interface meet ing all requirements of ITU T recommendations for G 703 Use a shielded E1 or T1 interface cable for 120 Ohm balanced connections to connect the Smar...

Страница 16: ...cond Power When lit indicates power is applied Run When lit the unit is in normal operation Flashes once per second during boot startup VoIP Link On indicates the gateway is registered to a SIP server...

Страница 17: ...etwork Ethernet Speed 1000 On when the Ethernet is connected to a 1000Mb network Ethernet Activity Flashes when data is received or transmitted at the corresponding Ethernet port PRI Link Status On in...

Страница 18: ...18 Chapter 2 Applications overview Chapter contents Introduction 19 Application Convert Legacy PBX to VoIP 19...

Страница 19: ...ode applications can be found online at www patton com smartnode Application Convert Legacy PBX to VoIP The SmartNode 4970A Series can be used to make and receive calls to and from the public ISDN net...

Страница 20: ...rmation 21 Network Diagram 21 IP related information 21 Software tools 22 AC Power Mains 22 Location and mounting requirements 22 Installing the gateway 22 Placing the SmartNode 22 Installing cables 2...

Страница 21: ...erations that you should take into account for planning are provided for several types of network interfaces are described in the following sections Network Diagram Draw a network overview diagram tha...

Страница 22: ...bles Allow sufficient space at the rear of the chassis for cable connections Additionally you should consider the need to access the unit for future upgrades and maintenance Note Under the rack mount...

Страница 23: ...RI port pin out and ISDN cables refer to Appendix C Cabling on page 43 and Appen dix D port pin outs on page 47 Connecting the 10 100 1000Base T Ethernet cable The SmartNode 4970A has automatic MDX au...

Страница 24: ...on page 30 to find out how to replace it with a com patible power cord 4 Connect the male end of the power cord to an appropriate power outlet 5 Verify that the green Power LED is lit see figure 5 Do...

Страница 25: ...26 Connecting the SmartNode to Your Laptop PC 26 Configure the Desired IP Address 27 Factory default IP Settings 27 Login 27 Changing the WAN IP address 27 Connecting the SmartNode to the Network 28...

Страница 26: ...e to Your Laptop PC First the SmartNode must be connected to the main power supply with the power cable Wait until the Power LED stops blinking and stays lit constantly Now the SmartNode is ready The...

Страница 27: ...g sections to change the addresses and network masks Login To access the SmartNode start the Telnet application Type either the default IP address into the address field of the Telnet application 192...

Страница 28: ...parameter 172 16 1 99 if ip WAN copy running config startup config 172 16 1 99 if ip WAN The SmartNode can now be connected to your network Connecting the SmartNode to the Network In general the Smart...

Страница 29: ...d its configuration from this server Note If your application is unique and not covered by any of Patton s configura tion templates you can manually configure the SmartNode instead of load ing a confi...

Страница 30: ...n support headquarters in the USA 31 Alternate Patton support for Europe Middle East and Africa EMEA 31 Warranty Service and Returned Merchandise Authorizations RMAs 31 Warranty coverage 31 Out of war...

Страница 31: ...7 Fax 1 253 663 5693 Alternate Patton support for Europe Middle East and Africa EMEA Online support available at www patton com E mail support e mail sent to support patton com will be answered within...

Страница 32: ...be issued upon receipt and inspection of the equipment 30 to 60 days We will add a 20 restocking charge crediting your account with 80 of the purchase price Over 60 days Products will be accepted for...

Страница 33: ...ompliance information Chapter contents Compliance 34 EMC 34 Safety 34 PSTN Regulatory 34 FCC Part 68 ACTA Statement 34 Industry Canada Notice 35 CE Declaration of Conformity 35 Authorized European Rep...

Страница 34: ...company will notify you in advance that temporary discontinuance of service may be required But if advance notice isn t practical the telephone company will notify the customer as soon as possible Al...

Страница 35: ...not prevent degradation of service in some situations Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier Any repairs or alterations mad...

Страница 36: ...Chapter contents Voice connectivity 37 Data connectivity 37 Voice processing signaling dependent 37 Fax and modem support 37 Voice signaling 38 Voice routing session router 38 IP services 38 Manageme...

Страница 37: ...rnet port All ports full duplex autosensing auto MDX Voice processing signaling dependent Up to 120 full duplex channels with Voice CODECS G 711 A Law Law 64 kbps G 726 ADPCM 16 24 32 40 kbps G 723 1...

Страница 38: ...ntgroups Call Distribution groups Number blocking Call Routing Criteria Interface Calling called party number Time of day day of week date ISDN bearer capability Various other information elements IEs...

Страница 39: ...and SSH access fully documented HTTP web management and firmware loading TFTP configuration firmware loading HTTPS configuration firmware provisioning SNMP v1 v2 v3 agent MIB II and private MIB Built...

Страница 40: ...40 Appendix C Cabling Chapter contents Introduction 41 Console 41 Ethernet 42 E1 PRI 43 T1 PRI 44...

Страница 41: ...rt as depicted in figure 8 Figure 8 Connecting a serial terminal Note See section Console port on page 47 for console port pin outs The interconnecting cables shall be acceptable for external use and...

Страница 42: ...switches PCs or other devices Figure 9 Typical Ethernet straight through cable diagram for 10 100Base T The interconnecting cables shall be acceptable for external use and shall be rated for the prope...

Страница 43: ...ure 11 on page 43 Figure 11 Connecting an E1 PRI port to an NT1 Hazardous network voltages are present in the PRI cables If you detach the cable detach the end away from the Smart Node or interface ca...

Страница 44: ...oltages are present in the PRI cables If you detach the cable detach the end away from the Smart Node or interface card first to avoid possible electric shock Network hazardous voltages may be present...

Страница 45: ...ual C Cabling Figure 14 T1 PRI crossover cable RJ 45 male RX Ring RX Tip RX Shield TX Ring TX Tip TX Shield N C N C RJ 45 male RX Ring RX Tip RX Shield TX Ring TX Tip TX Shield N C N C 1 2 3 4 5 6 7 8...

Страница 46: ...46 Appendix D Port pin outs Chapter contents Introduction 47 Console port 47 Ethernet 47 PRI port 48...

Страница 47: ...o flow control Figure 15 Console EIA 561 RJ 45 8 pin port Note N C means no internal electrical connection Ethernet Note Pins not listed are not used Table 6 Ethernet RJ45 socket 10 100Base T Pin Sign...

Страница 48: ...anual D Port pin outs PRI port NotePins not listed are not used 7 TRD3 8 TRD3 Table 8 PRI RJ 45 socket Pin USR 1 RX Ring 2 RX Tip 3 RX Shield 4 TX Ring 5 TX Tip 6 TX Shield Table 7 Ethernet RJ45 socke...

Страница 49: ...49 Appendix E SmartNode 4970A factory configuration Chapter contents Introduction 50...

Страница 50: ...actory configuration settings for the SmartNode device can be obtained with the following command through the CLI login admin password Enter 192 168 1 1 show config shipping config See Chapter 4 Initi...

Страница 51: ...dix F Reset Button Functions Chapter contents Introduction 52 Resetting the SmartNode device when it is operating and the Power LED is lit 52 Resetting the SmartNode device when it is initially powere...

Страница 52: ...ge 52 Factory reset which is followed by a device reboot as indicated by the fast blinking of all LEDs see section Resetting the SmartNode device when it is operating and the Power LED is lit on page...

Страница 53: ...after the last Reset button press an action will be performed based on the selected pattern Table 9 Results from pressing the Reset button Period Action A less than 1 second Reboot device B 1 to 4 sec...

Страница 54: ...ent Chapter contents End User License Agreement 55 1 Definitions 55 2 Title 55 3 Term 55 4 Grant of License 55 5 Warranty 56 6 Termination 56 7 Notices 56 8 Other Licenses 56 9 Unenforceable Provision...

Страница 55: ...re but are standard commercial software Except for the license use rights otherwise expressly provided in this Agreement no right title or interest in Patton Licensed Products is granted hereunder Lic...

Страница 56: ...ying all copies of the licensed Program s B Patton Electronics Company may terminate this Agreement should End User violate any of the provi sions of section 4 Grant of License on page 55 C Upon termi...

Страница 57: ...irrevocably submits to the exclusive jurisdiction of the courts of the State of Maryland USA for any dispute arising under or relating to this agreement and waives user s right to institute legal proc...

Отзывы: