Connecting the Ethernet Interface
24
CopperLink CL2300 User Manual
2
• Installing the CL2300
Connecting the Ethernet Interface
The Long Range Ethernet Extender has four unshielded RJ-45 Auto-MDIX10/100Base-T interfaces. These
ports are designed to connect directly to a 10/100Base-T device or network. You may connect this port to a
hub or PC using a straight through or crossover cable that is up to 328 ft. long.
.
1 TX+ (data output)
2 TX- (data output)
3 RX+ (data input)
4 (no connection)
5 (no connection)
6 RX- (data input)
7 (no connection)
8 (no connection)
1
2
3
4
5
6
7
8
Figure 9. CL2300 10/100Base-T RJ-45 Connector Pin-out
Connecting Power
The Long Range Ethernet Extender does not have a power switch, so it powers up as soon as it is plugged in.
The power connection is made via the barrel jack on the rear panel of the CL2300. No configuration is neces-
sary for the power supply.
An external AC or DC power supply is available separately. This connection is made via the barrel jack on the
rear panel of the CL2300. No configuration is necessary for the power supply.
DC power (supplied via the power supply jack to the CL2300) must meet the following requirements; DC
power supplied must be regulated 12VDC ±5%, 1.0A minimum. Center pin is +12V. The barrel type plug has
a 2.5/5.5/10mm I.D./O.D./Shaft Length dimensions.