manualshive.com logo in svg
background image

USER
MANUAL

MODEL 2042 Series

RS-530 to HSSI 
Interface Converter 

SALES OFFICE
(301) 975-1000
TECHNICAL SUPPORT
(301) 975-1007
http://www.patton.com

Part# 07M2042-UM
Doc# 07722U2-001,
Rev. D
Revised 10/25/06

C E R T I F I E D

An ISO-9001

Certified Company

Copyright © 2006

Patton Electronics Company

All Rights Reserved

Содержание 2042 Series

Страница 1: ...e Converter SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com Part 07M2042 UM Doc 07722U2 001 Rev D Revised 10 25 06 C E R T I F I E D An ISO 9001 Certified Company Copyrigh...

Страница 2: ...es expressed or implied and the installation or use of this product shall be deemed an acceptance of these terms by the user 1 1 RADIO AND TV INTERFERENCE The Model 2042 generates and uses radio frequ...

Страница 3: ...ts synchronous data rates up to 10Mbps Transparent to synchronous protocol DB 25 and HD 50 connectors with integral 6 foot 1 8m cable Two versions available Model 2042MC MT Connects RS 530 DTE to HSSI...

Страница 4: ...ew Driver to Open the Model 2042 Case Figure 2 Using a Small Screw Driver to Open the Model 2042 Case 6 3 1 CONFIGURATION SWITCHES MODEL 2042MC MT The Model 2042MC MT has miniature DIP switches that y...

Страница 5: ...Off Not a Valid Setting Off On Data Skips Sync Circuit On Off Data passes through sync circuit On On Not a Valid Setting 2042MC MT DIP SWITCH SUMMARY TABLE Position Function Factory Default S1 Clock S...

Страница 6: ...Function Factory Default S1 Gapped Clock On S2 Gapped Clock Off S3 Sync Method Off S4 Sync Method On No Gapped Clock Bypass Sync Circuit 10 4 0 INSTALLATION The Model 2042 is designed to connect RS 53...

Страница 7: ...w shows the positions of the LEDs Following Figure 9 is a description of each LED Status Glows green to indicate that both DTR from the DTE device and DSR from the DCE device are active This LED will...

Страница 8: ...imply converts and passes the data through the communication link The DCEs must be configured to perform to the appropriate loopback diagnostic 13 5 2 1 Local Loopback LL The Local Loopback LL test ch...

Страница 9: ...IEC CE emissions Power Unit will require an external desk top power supply Temperature Range 0 to 50 C 32 122 F Humidity 5 to 95 non condensing Size 3 0 L x 1 8 W x 0 8 H 7 6 X 4 4 X 1 9 CM Approval...

Страница 10: ...eserved for Future Use 39 43 Reserved for Future Use 19 Reserved for Future Use 44 Reserved for Future Use 20 23 Reserved for Future Use 45 48 Reserved for Future Use 24 TM Test Mode Indication A 49 T...

Страница 11: ...19 20 APPENDIX D PATTON ELECTRONICS MODEL 2042MT MC BLOCK DIAGRAM APPENDIX E PATTON ELECTRONICS MODEL 2042MC MT BLOCK DIAGRAM...

Страница 12: ...__________________________________________ ________________________________________________________ 21 NOTES ________________________________________________________ __________________________________...

Отзывы: