manualshive.com logo in svg
background image

The DCE/DTE strap is located on the top side of the 1089/D pc

board (See Figure 8, below).  The arrows on the top of the strap indi-
cate the configuration of the X.21 port (for example, if the DCE arrows
are pointing toward the DB-15 connector, the X.21 port is wired as a
DCE).  Change the DCE/DTE orientation by pulling the strap out of its
socket, rotating it 180º, then plugging the strap back into the socket.
You will see that the DCE/DTE arrows now point in the opposite direc-
tions, showing the new configuration of the X.21 port.  

To close the

case, fit the 2 halves together snugly and snap them back in place.

4.4  CONNECTING POWER

The Model 1089 (all versions) are available with Universal AC

(100-240VAC), 120VAC, 230VAC or -48VDC power options.  This sec-
tion describes these options.

4.4.1  Universal AC Power (100-240VAC)

The Model 1089 uses a 5VDC, 2A universal input 100-240VAC,

power supply (center pin is +5V).  The universal input power supply
has a male IEC-320 power entry connector.  This power supply con-
nects to the Model 1089 by means of a barrel jack on the rear panel.
Many international power cords are available for the universal power
supply (Please refer to Appendix B for country-specific power cords.  

The Model 1089 powers up as soon as it is plugged into an AC

outlet--there is no power switch.

13

4.4.2  120 VAC Power (US)

The 100-132 VAC adapter supplied with the U.S. version of the

Model 1089 is a wall mount type and may be plugged into any
approved 120 VAC wall jack.

4.4.3  230 VAC Power (International)

The 230 VAC adapter supplied with the International version of the

Model 1089 is a wall mount type and may be plugged into any
approved 230 VAC wall jack.

4.4.4  DC Power 

The 36-60 VDC DC to DC adapter is supplied with the DC version

of the Model 1089.  The black and red leads plug into a DC source
(nominal 48VDC) and the barrel power connector plugs into the barrel
power supply jack on the rear panel of the 1089. (See Figure 9).

14

DCE/DTE Strap

DB-15 Connector

Figure 8.

Setting the DCE/DTE Strap

Figure 9.

Connecting DC Power to the 48V-PSM DC Power Supply.

WARNING!

There are no user-serviceable parts in the

power supply section of the Model 1089. Fuse replacement
should only be performed   by qualified service personnel.
Contact Patton Electronics Technical support at (301)975-
1007, via our web site at http://www.patton.com, or by e-mail
at [email protected], for more information.

To Power

Supply Jack

To -48VDC

Source

-Vin

+Vin

SWITCHING POWER SUPPL

Y

MODEL

 : SYD1

106-0505

INPUT

 : 36-60V      0.2A

 MAX

OUTPUT

 : +5V       1.0A

OUTPUT

 POWER : 5W MAX

S/N

: G01234567890

                             

MADE IN CHINA

 BY

 SUNNY

Black lead (-V)

Red lead (+V)

Barrel power connector

Содержание 1089/C

Страница 1: ...L Modem with V 35 or X 21 Interface Part 07M1089 UM Doc 03208U2 001 Rev C Revised 10 24 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com C E R T I F I E D C E R T I F I...

Страница 2: ...acement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost pro...

Страница 3: ...Front Panel Status Indicators Small Convienent Desktop Unit CE Marked 2 2 DESCRIPTION The Patton Electronics HDSL Rocket provides high speed 2 wire connectivity to ISPs PTTs and corporations using HDS...

Страница 4: ...tches Front Back On S2 S3 Off 3 1 1 Configuration DIP Switch Set S2 The configuration switches on S2 allow you to specify the Clocking Mode and to enable disable Local and Remote Loop requests from th...

Страница 5: ...mmarizes default positions of DIP Switch S3 Detailed descriptions of each switch follow the table Switch S3 1 DTE Rate Use Switch S3 1 through S3 6 to set the DTE bit rate S3 1 S3 2 S3 3 S3 4 S3 5 S3...

Страница 6: ...e end of the twisted pair DSL span must be set for the same DTE rate 2 To function properly the Model 1089 needs one twisted pair of metallic wire This twisted pair must be unconditioned dry metallic...

Страница 7: ...TERFACE Model 1089 D supports X 21 serial port connections This section describes how to connect the serial ports to your X 21 equipment 4 3 1 Connecting the Model 1089 D X 21 to a DCE or DTE Device T...

Страница 8: ...del 1089 powers up as soon as it is plugged into an AC outlet there is no power switch 13 4 4 2 120 VAC Power US The 100 132 VAC adapter supplied with the U S version of the Model 1089 is a wall mount...

Страница 9: ...very 200 ms if the DTE Rate is set to an unsupported settings TM glows yellow to indicate that the Model 1095 has been placed in Test Mode The unit can be placed in test mode by the local user or by t...

Страница 10: ...op the data is looped back to the line but it is also allowed to pass through to the framer and to the remote DTE 17 Restart Procedure The restart procedure is in place to allow the and Time Outs unit...

Страница 11: ...the second path data presented at the far end DTE will be transmitted to the local DTE and then looped back within the local DTE Loop Control block with the Processor After the Local Loop is deselect...

Страница 12: ...Request signal is sent to the remote unit The Remote unit then responds with an RDL Acknowledge command and the link is established Data originates at the local DTE and is looped at the Remote PROCESS...

Страница 13: ...nds of the link Once a 511 511E pattern is selected on one end of the link the pattern generator will begin transmitting unframed 511 511E through the line to the Remote end A possible problem with th...

Страница 14: ...rn generator and detector with error injection mode con trolled by front panel switch Local and Remote Loopback control by either a front panel switch or from the DTE interface LED Status The followin...

Страница 15: ...d J 0805SW Switzerland Power Cord L 07M1089 C User Manual A AP PP PE EN ND DI IX X C C PATTON ELECTRONICS MODEL 1089 C INTERFACE PIN ASSIGNMENTS V 35 INTERFACE M 34 Female Connector DCE Orientation Pi...

Страница 16: ...NCES 29 30 Line Rate DTE Rates kbps feet miles km feet miles km 144 64 128 20700 3 9 6 2 24500 4 6 7 3 272 192 256 17400 3 3 5 2 24200 4 5 7 2 400 320 384 15100 2 9 4 6 22600 4 2 6 7 528 448 512 14900...

Страница 17: ...Copyright 2006 Patton Electronics Company All Rights Reserved...

Отзывы: