5.3.3  Using the V.52 (BER) Test Pattern Generator

To use the V.52 BER tests in conjunction with the Remote Digital

Loopback tests (or with Local Line Loopback tests), follow these
instructions:

1.  

Locate the “511/511E” toggle switch on the front panel of the 
1089 and move it UP.  This activates the V.52 BER test mode
and transmits a “511” test pattern into the loop.  If any errors 
are present, the local modem’s red “ER” LED will blink 
sporadically.  

2.   If the above test indicates no errors are present, move the 

V.52 toggle switch DOWN, activating the “511/E” test with 
errors present.  If the test is working properly, the local 
modem's red “ER” LED will glow.  A successful “511/E” test 
will confirm that the link is in place, and that the Model 
1095’s built-in “511” generator and detector are working 
properly.

25

26

A

AP

PP

PE

EN

ND

DIIX

X   A

A

PATTON ELECTRONICS MODEL 1089/C AND 1089/D

SPECIFICATIONS

Clocking Modes:  

Internal, External, or Receive Recovered

DTE Rate:

All 64k steps from 64 to 2304 kbps

DTE Interface:

V.35 (Model 1089/C), DCE Orientation;
X.21 (Model 1089/D), DCE or DTE 
Orientation depending upon orientation of 
pc-board mounted daughter board

DTE Connector:

M/34 Female (Model 1089/C)
D-Sub-15 Female (Model 1089/D)

Diagnostics:

V52 compliant (511/511E) pattern generator
and detector with error injection mode con-
trolled by front panel switch, Local and 
Remote Loopback control by either a front 
panel switch or from the DTE interface

LED Status:

The following LEDs are displayed on the 
front panel:

DSL Link (Green Active) - 

DSL Link Active

TD, RD (Yellow/Green) - 

Idle Yellow

NS (Red Active) - 

No signal DSL Link

ER (Flashing Red) - 

CRC error during nor-

mal operation, bit error during pattern gen-
eration test

TM (Active Yellow) - 

Test Mode Enabled

Configuration:

Externally accessible dip switches or SNMP
managed through 1095RC

Power:

+5V External desk top power supply, 90-
260VAC, 50-60 Hz (Universal Input), 10W 
or -48VDC

Compliance:

FCC Part 15, CE 

Transmission Line:

Single Twisted Pair

Line Coding:

2B1Q

Line Rates (DSL line): 

144, 272, 400, 528, 784, 1040, 1168kbps

Line Interface:

Transformer coupled, 1500 VAC isolation

mDSL Physical 
Connection:  

RJ-45, 2 wire, polarity insensitive pins 4 
and 5

Environment:  

Operating temperature 0-50°C; humidity 5-
95% non-condensing; altitude, 0-15, 000 
feet (0-4600 m)

NOTE:

The above V.52 BER tests can be used independently

of  the Remote Digital Loopback tests.  This requires two opera-
tors:  (1) to initiate and monitor the tests at the local Model 1089,
and (2) to do the same at the remote Model 1089.  In this case,
the test pattern sent by each Model 1089 will not be looped back,
but will be transmitted down the line to the other Model 1089.
While one operator initiates test, the other monitors for errors.

Содержание 1089/C

Страница 1: ...L Modem with V 35 or X 21 Interface Part 07M1089 UM Doc 03208U2 001 Rev C Revised 10 24 06 SALES OFFICE 301 975 1000 TECHNICAL SUPPORT 301 975 1007 http www patton com C E R T I F I E D C E R T I F I...

Страница 2: ...acement as described above Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product These damages include but are not limited to the following lost pro...

Страница 3: ...Front Panel Status Indicators Small Convienent Desktop Unit CE Marked 2 2 DESCRIPTION The Patton Electronics HDSL Rocket provides high speed 2 wire connectivity to ISPs PTTs and corporations using HDS...

Страница 4: ...tches Front Back On S2 S3 Off 3 1 1 Configuration DIP Switch Set S2 The configuration switches on S2 allow you to specify the Clocking Mode and to enable disable Local and Remote Loop requests from th...

Страница 5: ...mmarizes default positions of DIP Switch S3 Detailed descriptions of each switch follow the table Switch S3 1 DTE Rate Use Switch S3 1 through S3 6 to set the DTE bit rate S3 1 S3 2 S3 3 S3 4 S3 5 S3...

Страница 6: ...e end of the twisted pair DSL span must be set for the same DTE rate 2 To function properly the Model 1089 needs one twisted pair of metallic wire This twisted pair must be unconditioned dry metallic...

Страница 7: ...TERFACE Model 1089 D supports X 21 serial port connections This section describes how to connect the serial ports to your X 21 equipment 4 3 1 Connecting the Model 1089 D X 21 to a DCE or DTE Device T...

Страница 8: ...del 1089 powers up as soon as it is plugged into an AC outlet there is no power switch 13 4 4 2 120 VAC Power US The 100 132 VAC adapter supplied with the U S version of the Model 1089 is a wall mount...

Страница 9: ...very 200 ms if the DTE Rate is set to an unsupported settings TM glows yellow to indicate that the Model 1095 has been placed in Test Mode The unit can be placed in test mode by the local user or by t...

Страница 10: ...op the data is looped back to the line but it is also allowed to pass through to the framer and to the remote DTE 17 Restart Procedure The restart procedure is in place to allow the and Time Outs unit...

Страница 11: ...the second path data presented at the far end DTE will be transmitted to the local DTE and then looped back within the local DTE Loop Control block with the Processor After the Local Loop is deselect...

Страница 12: ...Request signal is sent to the remote unit The Remote unit then responds with an RDL Acknowledge command and the link is established Data originates at the local DTE and is looped at the Remote PROCESS...

Страница 13: ...nds of the link Once a 511 511E pattern is selected on one end of the link the pattern generator will begin transmitting unframed 511 511E through the line to the Remote end A possible problem with th...

Страница 14: ...rn generator and detector with error injection mode con trolled by front panel switch Local and Remote Loopback control by either a front panel switch or from the DTE interface LED Status The followin...

Страница 15: ...d J 0805SW Switzerland Power Cord L 07M1089 C User Manual A AP PP PE EN ND DI IX X C C PATTON ELECTRONICS MODEL 1089 C INTERFACE PIN ASSIGNMENTS V 35 INTERFACE M 34 Female Connector DCE Orientation Pi...

Страница 16: ...NCES 29 30 Line Rate DTE Rates kbps feet miles km feet miles km 144 64 128 20700 3 9 6 2 24500 4 6 7 3 272 192 256 17400 3 3 5 2 24200 4 5 7 2 400 320 384 15100 2 9 4 6 22600 4 2 6 7 528 448 512 14900...

Страница 17: ...Copyright 2006 Patton Electronics Company All Rights Reserved...

Отзывы: