GB
- 153 -
11. Troubleshooting guide
Faults
Cause
Remedy
The equip-
ment does
not start
- Power supply not con-
nected
- Floating switch does
trigger
- Check power supply
- Raise position of
fl
oa-
ting switch
The equip-
ment does
not pump
- Intake sieve clogged
- Discharge hose kinked
- Clean intake sieve with
water jet
- Unkink the hose
The equip-
ment does
not cut out
- Floating switch cannot
sink
- Place equipment cor-
rectly on shaft bottom
Insu
ffi
cient
pumping rate
- Intake sieve clogged
- Performance reduced
due to heavily conta-
minated and abrasive
water impurities
- Clean intake sieve
- Clean equipment and
replace wear parts
The equip-
ment swit-
ches o
ff
after
brie
fl
y run-
ning
- Motor circuit-breaker
switches the equipment
o
ff
due to excessive
water contamination
- Water temperature
too high; motor circuit-
breaker switches the
equipment o
ff
- Unplug power plug and
clean equipment and
shaft
- Ensure that maximum
permissible water tem-
perature (35 °C) is not
exceeded
Anl_PE_SW_3030_SPK7.indb 153
Anl_PE_SW_3030_SPK7.indb 153
26.03.2020 10:19:56
26.03.2020 10:19:56
Содержание PE-SW 3030
Страница 4: ...4 2 3 18 Anl_PE_SW_3030_SPK7 indb 4 Anl_PE_SW_3030_SPK7 indb 4 26 03 2020 10 19 30 26 03 2020 10 19 30...
Страница 158: ...158 Anl_PE_SW_3030_SPK7 indb 158 Anl_PE_SW_3030_SPK7 indb 158 26 03 2020 10 19 57 26 03 2020 10 19 57...
Страница 159: ...159 Anl_PE_SW_3030_SPK7 indb 159 Anl_PE_SW_3030_SPK7 indb 159 26 03 2020 10 19 57 26 03 2020 10 19 57...
Страница 160: ...160 Anl_PE_SW_3030_SPK7 indb 160 Anl_PE_SW_3030_SPK7 indb 160 26 03 2020 10 19 57 26 03 2020 10 19 57...