Valve fails to refill brine tank
Cause
Solution
Improper brine refill time setting
Verify that refill time corresponds to salt level and amount
of resin
Plugged refill flow control
Clean flow control
System uses too much salt
Cause
Solution
Excessive water in brine tank
Refer to problem “Excessive water in brine tank”
Unit regenerates too frequently
Check household for excessive or unexpected water usage
—
leaky toilet fill valves, T&P Relief drainage, Reverse Osmosis
processors, humidifiers, plumbing leaks etc...
Salty water to service
Cause
Solution
Excessive water in brine tank
Refer
to problem “Excessive water in brine tank”
Injector undersized
Verify injector selection
Improper brine/slow rinse time setting Verify that brine/slow rinse time corresponds to the
proper salt level and amount of resin
Improper fast rinse time setting
Verify that fast rinse time corresponds to the proper
salt level and amount of resin