background image

System Control & Operation 

Your  Patriot Pro  SXTI  System  incorporates  a  highly  sophisticated 
microprocessor control  system,  making  it  efficient  and  reliable.  All  system 
settings  are  pre-programmed  at  the  factory  and  then  carefully  calibrated  by 
your  installer  for  your specific  application.  Your 

Patriot Pro

  SXTI  System 

incorporates  flash  EEPROM memory  and  an innovative  power  backup  system, 
which  means  that  your  system programming should never have to be reset, even in 
the event of an extended power outage.

In 

normal operating mode

, the display shows the time of day and the 

capacity remaining. The system observes your water usage through the 
on-board flow meter and makes intelligent decisions on when and how 
to clean based on its based programming profile and observations of 
your water usage habits. 

Cleaning mode 

In 

cleaning mode 

the display shows the current cleaning cycle step and the 

remaining time for that cycle to execute. 

Flow meter 

In 

service mode 

the display will show the time of day and remaining capacity; 

the remaining capacity 

counter counts backwards in gallons. By opening a faucet downstream 

of the system, the correct functioning of the flow meter can be checked 

by means of this counter. 

Diagnostic Mode 

In diagnostic mode the system will display various operational statistics 

and diagnostic data. 

Power-Failure Handling 

In the event of a power failure, your system’s integrated Snapshot memory system 

will retain all programmed data for an indefinite period of time. The system will 

maintain the correct time of day during a period of several hours. In the case of a 

prolonged power failure, the time of day might not be maintained; if this happens, the 

time of day indication will, when the power supply is re-established, be 

flashing

indicating that the time of day needs to be reset. All other programming is 

unaffected. 

Critical Software/Hardware failure 

In the event of a critical software failure, the system display will be completely blank: 

Call your local service provider for help. 

Normal Operating Mode

 

Содержание Pro SXTi

Страница 1: ...Patriot Pro SXTi Service Manual Revised 2019...

Страница 2: ...get to study the long term health effects of the more than 70 000 harmful chemicals that can be found in use today Approximately 1 000 new synthetic chemical compounds are entering the industrial mark...

Страница 3: ...loors Hardness and other dissolved solids combine to form the residue you see as spots on glasses crockery cutlery and shower enclosures Hard water harms fabrics Laundry washed in hard water takes on...

Страница 4: ...rms an insulating layer that prevents the burners or heating elements from heating the water efficiently Just 1 8 of scale inside the tank can require up to 30 more fuel to heat the water to the desir...

Страница 5: ...maged Clothing Excessive Soap Consumption Pipe Scaling Faucet and Fixture Damage Skin Problems Unpalatable Food Undesirable Tastes and Odors Premature Appliance Failure Unsatisfactory Laundry Results...

Страница 6: ...become available Reliable The mechanical subsystem in the Patriot Pro is revolutionary in its own right The Patriot Pro is built around Open platform TM technology building on a 40 year legacy of reli...

Страница 7: ...sibly even compromise system functionality Consult with your local water professional to decide on the best salt for your application Pur Gard The Pur Gard injection feeder should be kept full to ensu...

Страница 8: ...sumption habits always maximizing efficiency and performance while providing you with the water quality that you deserve Pur Gard is designed to Clean ion exchange resin without damaging structured ma...

Страница 9: ...algae mold and fungus that can enter the system through safe city water salt or even from the air These additional contaminants slowly accumulate in your softener and can even colonize it with a biof...

Страница 10: ...ystem Observe flow of water from the bathtub Water will become a dark brown black color This color is caused by the system disinfectant preservative as well as dust from shipping handling Allow water...

Страница 11: ......

Страница 12: ...ring regeneration Data Display During Service Mode Displays Time of Day and capacity remaining During cleaning mode Counts remaining cycle time PM Indicator Lit when time being displayed is after noon...

Страница 13: ...at cycle to execute Flow meter In service mode the display will show the time of day and remaining capacity the remaining capacity counter counts backwards in gallons By opening a faucet downstream of...

Страница 14: ...ogramming parameters DO Set the anti bacterial day override setting The system will cycle at least once during the time interval set here If you don t use any water the system will not use any salt RT...

Страница 15: ...RATE Displays the current real time flow rate through the system PF PEAK FLOW RATE Displays the highest flow observed by the system since the last regeneration HR HOURS IN SERVICE Displays the total n...

Страница 16: ...acement of the calcium and magnesium ions in the water by an equivalent number of sodium ions The Softening process may be illustrated by the following equation R2 Na Ca HCO3 2 R2 Ca 2NaHCO3 Sodium Io...

Страница 17: ...mation During Service The control center constantly monitors water usage in your home learning your lifestyle and adapting itself to ensure that you have a consistent supply of softened water The cont...

Страница 18: ...e water in the home during this time Backwash Your system rapidly discharges water upwards through the resin media bed and to the drain This backwash step ensures that trapped sediment and broken resi...

Страница 19: ...o clean Valve fails to draw brine Refer to problem Valve fails to draw brine Decreasing exchange capacity of resin Clean augment or replace resin bed No salt in brine tank Add salt Leak at riser tube...

Страница 20: ...nks restrictions or obstructions Leak in brine line Verify brine line and connections for air leakage Insufficient water in brine tank Refer to problem Valve fails to refill brine tank Excessive water...

Страница 21: ...sehold for excessive or unexpected water usage leaky toilet fill valves T P Relief drainage Reverse Osmosis processors humidifiers plumbing leaks etc Salty water to service Cause Solution Excessive wa...

Страница 22: ...up in resin tank Clean resin bed and control valve increase regeneration frequency Increase Pur Gard dosage rate Plugged lower and or upper distributor Verify that distributors are free of debris Cru...

Страница 23: ...quired by applicable law Intermountain Soft Water shall not be liable for any damages whatsoever including without limitation loss time inconvenience expenses such as telephone calls labor or material...

Отзывы: