background image

- 13 -

                                     PATON VDI SERIES ECO  DC MMA 

 

No welding currents. 
The power is switched on; 
the green indicator lights. 

Welding cables are not 
connected. 

Check the state of electric 
connectors. 

The earthing terminal is not 
properly connected or is not 
connected to the workpiece. 

Properly connect the earthing 
terminal to the workpiece. 

No welding currents. 
The power is switched on; 
the yellow indicator lights. 

Triggering one of the 
temperature sensors 

Wait when the machine to cool 
down; then it will 
automatically switch on again 

Insufficient supply of cooling air  To ensure sufficient ventilation 

Faulty thermal sensor 

Contact your Service Centre 

Improper arc starting in the 
manual consumable-
electrode arc welding; the 
green indicator flashes. 

The power supply voltage is 
close to the minimum allowable 
voltage of 165 V. 

If it is not possible to increase 
the cross-section of the 
conductors of the power cable, 
decrease the set welding 
current to the value which is 
sufficient for arc staring.  
Select the welding electrode 
with consideration for the 
welding current. 

Random arc extinction 
during welding

 

The arc voltage is too high for 
the electrode used. 

Use another electrode or a 
welding unit rated at higher 
power. 

The electrode sticks to the 
workpiece 

The welding current is too low. 

Set the proper welding current. 

 

Low quality of the weld 
(metal scattering)

 

The polarity of voltage across 
the electrode is improper. 

Change the polarity across the 
electrode according to the 
instructions of the electrode 
manufacturer. 

 

11. SAFETY INSTRUCTIONS 

GENERAL INFORMATION 

This device may only be used for the purposes for which it was created. This appliance is intended for 
use  by  persons  with  the  requisite  qualifications.  It  is  the  responsibility  of  the  qualified  personnel  to 
install,  service  and  repair.  Please  read  this  manual  carefully  before  installing  and  using  this  product. 
Failure  to  follow  the  instructions  in  this  manual  may  result  in  serious  personal  injury,  death  and 
damage to the unit itself. Incorrect installation, maintenance and operation resulting in damage to the 
device - the manufacturer is not liable. 

 

 

Содержание VDI-160E

Страница 1: ...1 PATON VDI SERIES ECO DC MMA Operation Manual Inverter rectifiers PATON VDI 160E VDI 200E VDI 250E 4 Contents...

Страница 2: ...OVERED ELECTRODE ARC WELDING PROCESS MMA 8 3 1 INCREASED CURRENT ARC STARTING HOT START 9 3 2 REDUCED WELDING VOLTAGE FUNCTION ARC FORCE 9 3 3 PROTECTION AGAINST ELECTRODE STICKING ANTI STICK 10 4 MAI...

Страница 3: ...es production are in conformity with the product sample detailed in this report The applicant should hold the whole technical report at disposal of the competent all the right Applied EC Directives 20...

Страница 4: ...r rectifiers PATON VDI 160E VDI 200E VDI 250E optimized for direct current manual arc welding MMA This ECO series of devices designed for demanding users who wants the most compact and functional devi...

Страница 5: ...the printed circuit boards with electronic elements are impregnated with two layers of high quality varnish in order to provide the high reliability of the welding unit during its service life 7 The...

Страница 6: ...status of indicator a constantly lit green machine is ready to work b blinks green when striking there is no mains voltage c constantly lit yellow overheating of the source d does not light up no pow...

Страница 7: ...nit is protected against ingress of foreign particles more than 5 5 mm in size and the internal elements of the unit are protected against moisture so the unit is allowed for outdoor operation WARNING...

Страница 8: ...e welding unit see Subsection 1 1 Technical characteristics Connect the welding unit to an electrical outlet that is made for three wire earthing plugs 3 MANUAL CONSUMABLE ELECTRODE ARC WELDING MODE M...

Страница 9: ...at the increased current arc starting stage is 90 0 33 90 120 A 3 2 REDUCED VOLTAGE WELDING FUNCTION ARC FORCE The advantages ensured by the reduced voltage welding function are the following The enh...

Страница 10: ...ctrical outlet of the power supply system Wait for about 5 minutes until static charges in the unit circuits are removed and then perform the maintenance operations After completion of works with the...

Страница 11: ...rding to State Norm for 5 years The welding unit should be stored in a dry closed room at an ambient temperature not lower than 5 C In the room acid vapors and chemically active substances should not...

Страница 12: ...ble 3 m in length 1 pcs 2 Shoulder carry belt 1 pcs 3 Brand corrugated box PATON 1 pcs 4 Welding cable with an electrode holder 3 m in length 1 pcs 5 Welding cable with an earthing terminal 3 m in len...

Страница 13: ...is sufficient for arc staring Select the welding electrode with consideration for the welding current Random arc extinction during welding The arc voltage is too high for the electrode used Use anoth...

Страница 14: ...non flammable radiation absorbing screens VAPOUR AND GASES MAY BE DANGEROUS The resulting smoke and harmful gases should be removed from the work area by means of specialized equipment do not cover t...

Страница 15: ...ny maintenance work on the unit Removing the outside cover of the device while it is connected to the network and using the device with the lid removed is forbidden NOISE ASSOCIATED WITH WELDING CAN B...

Страница 16: ...PATON VDI SERIES ECO DC MMA 16 12 ELECTRICAL SCHEMATIC DIAGRAM 230 V CURRENT BIS 0331 BVR 0331 BPK 0332...

Страница 17: ...the accumulation of conductive dust inside coal dust metal chips etc In case of attempting to repair its nodes and or replacement of electronic components Once on six months clean internal parts and c...

Страница 18: ...above recommendations may result in the imposition of fines in accordance with applicable regulations If you would like to return the unit for disposal please contact your nearest point of sale or co...

Страница 19: ...e Date of reception of the welding unit for repair _____ __________ 20 ___ year _______________________ signature Faults detected ______________________________________________________________________...

Страница 20: ...__________ Tel Technical support 48 889 226 032 Address of the service center 38500 Poland Sanok Zamenhofa 9 Street Date of reception of the welding unit for repair _____ __________ 20 ___ year ______...

Отзывы: