6 | P a g e
PATON
®
VDI SERIES MINI DC MMA
1
– The control for smoothly adjusting welding current;
2
– The indicator of operating condition of the welding unit:
a)
Continuously lights green when the welding unit is in the operating mode;
b)
Alternately flashes green and yellow when the power supply voltage is insufficient for arc
starting;
c)
Continuously lights yellow when the welding unit is overheated;
d)
Does not light when the power supply voltage is not available;
А (+) –
The bayonet connector socket:
a)
For connecting the electrode cable (or the grounding cable in some cases when special
electrodes are used for welding) for the manual arc welding
(MMA);
B (-) –
The bayonet connector socket:
b)
for connecting the grounding cable (or the electrode cable in some cases when special
electrodes are used for welding) for the manual arc welding
(MMA).
3
– The push-button switch for switching on and off the welding unit (the push-button is without a
light indicator; the colour of the push-button is decorative).
2.
SETTING THE WELDING UNIT INTO OPERATION
ATTENTION!!!
Read
Section 11
, "Safety instructions", before setting the
welding unit into operation.
2.1 PROPER USE
The welding unit is designed exclusively for manual covered-electrode arc welding.
Any other use of the welding unit is considered as improper. The manufacturer of the welding unit is
not responsible for damages caused by any improper use of the unit.
The use of the welding unit is proper if all the requirements of this Operation Manual are satisfied.
ATTENTION!!!
Do not use the welding unit to unfreeze pipes.
2.2 REQUIREMENTS FOR INSTALLATION
The welding unit is protected against ingress of foreign particles more than 12.5 mm in size.
The welding unit is allowed for outdoor operation. The internal electrical and electronic elements of
the welding unit are protected against moisture but are not protected against atmospheric condensate
drops.
ATTENTION!
When operating the welding unit in cold season, after the unit
was switched off and cooled, condensate may appear inside the unit, so switch
on the welding unit only 3 – 4 hours after the switching off!!!