-25 -
PATON
PRO-315
MMA/TIG/MIG/MAG
b) OFF
8) [Po.P] current pulse power = OFF (default)
a) 0 [OFF] ... 80% (1% increments)
9) [Fr.P] current pulsation frequency = 5.0 Hz (default)
a) 0.2 ... 500 Hz (dynamic increments of 0.1 Hz ... 1 Hz)
10) [dut] filling factor (duty cycle) is the percentage of the current pulse time to the
period of the following pulses = 50% (default)
a) 20 ... 80% (1% increments)
TIG welding mode
0) [-2-] - the main display parameter CURRENT = 100 A (default)
a) 15 ... 315A (change step 1 A) for PRO-315
1) [t.uP] current rise time = 1.0 s (default)
a) 0.1 ... 15.0 sec (0.1 sec increments)
2) [Po.P] current pulse power = OFF (default)
a) 0 [OFF] ... 80% (1% increments)
3) [Fr.P] current pulsation frequency = 10.0 Hz (default)
a) 0.2 ... 500 Hz (dynamic increments of 0.1 Hz ... 1 Hz)
4) [dut] filling factor (duty cycle) is the percentage of the current pulse to the
period of the following pulses = 50% (default)
a) 20 ... 80% (1% increments)
MIG/MAG welding mode
0) [-3-] the main display parameter VOLTAGE = 19.0 V (default)
a) 12.0 ... 28.0 V (0.1 V increments)
1) [t.uP] voltage rise time = 0.1 s (default)
a) 0.1 ... 5.0 sec (0.1 sec increments)
2) [t.dn] voltage reduction time = 0.1 sec (default)
a) 0.1 ... 5.0 sec (0.1 sec increments)
3) [Po.P] voltage pulse power = OFF (default)
a) 0 [OFF] ... 80% (1% increments)
4) [Fr.P] voltage pulsation frequency = 20.0 Hz (default)
a) 5 Hz ... 500 Hz (1 Hz increment)
5) [dut] filling factor (duty cycle) is the percentage of the voltage pulse to the
period of the following pulses = 50% (default)
a) 20 ... 80% (1% increments)