background image

          

‐ 

9

 ‐

      

PATON

 

PRO-series

 

DC

 

MMA/TIG/MIG/MAG

 

3.3

 

ARC

 

FORCE

 

FUNCTION

 

Advantages:

 

‐ 

enhanced

 

short

arc

 

welding

 

stability;

 

‐ 

better

 

transfer

 

of

 

metal

 

drops

 

into

 

the

 

weld

 

pool;

 

‐ 

better

 

arc

 

striking;

 

‐ 

reduced

 

risk

 

of

 

electrode

 

sticking;

 

however,

 

it

 

is

 

not

 

the

 

Anti

Stick

 

function,

 

which

 

will

 

be

 

explained

 

in

 

the

 

next

 

paragraph;

 

‐ 

manual

 

adjustment;

 

allows

 

setting

 

the

 

function

 

level

 

to

 

minimum

 

value,

 

thus

 

reducing

 

power

 

consumption

 

(although

 

insignificantly),

 

as

 

well

 

as

 

heat

 

input

 

concentration

 

when

 

welding

 

thin

 

metal

 

pieces.

 

This

 

reduces

 

the

 

risk

 

of

 

burn

through,

 

but

 

also

 

reduces

 

stability

 

of

 

short

 

arc

 

burning

 

(the

 

machine

 

becomes

 

similar

 

to

 

a

 

transformer

 

source).

 

The

 

function

 

can

 

also

 

be

 

increased

 

to

 

maximum

 

value

 

for

 

even

 

better

 

stability

 

of

 

short

arc

 

burning,

 

but

 

this

 

requires

 

for

 

better

 

supply

 

mains

 

and

 

increases

 

the

 

risk

 

of

 

work

 

piece

 

burn

through.

 

The

 

result

 

is

 

achieved

 

by

 

the

 

following

 

means:

 

Due

 

to

 

reduction

 

of

 

arc

 

voltage

 

below

 

the

 

minimum

 

permissible

 

voltage

 

of

 

stable

 

arc

 

burning,

 

arc

 

current

 

increases

 

by

 

the

 

default

 

value

 

of

 

+40%.

 

In

 

the

 

additional

 

settings

 

you

 

can

 

change

 

both

 

Arc

 

Force

 

magnitude

 

[Ar.F]

 

and

 

trigger

 

level

 

of

 

this

 

function

 

[u.AF].

 

Do

 

not

 

set

 

Arc

 

Force

 

magnitude

 

and

 

trigger

 

level

 

to

 

unnecessarily

 

high

 

value,

 

because

 

at

 

high

 

limit

 

values,

 

especially

 

during

 

welding

 

with

 

thin

 

electrodes

 

less

 

than

 Ф

3.2

 

mm

 

in

 

diameter,

 

affects

 

actuation

 

of

 

Anti

Stick

 

function,

 

which

 

will

 

be

 

explained

 

in

 

the

 

next

 

paragraph.

 

See

 

paragraph

 

6.1

 

for

 

sequence

 

of

 

changing

 

the

 

value

 

of

 

any

 

function

 

in

 

the

 

current

 

welding

 

mode.

 

Содержание PRO-160

Страница 1: ......

Страница 2: ...2 TIG LIFT arc striking function 13 4 3 Arc current fade in function 13 4 4 Pulsed current welding function 14 5 Semiautomatic metal inert active gas welding MIG MAG 15 5 1 Welding cycle MIG MAG 17 5...

Страница 3: ...t 0 6 mm at most 1 75 1 5 115 2 155 2 5 195 4 310 6 465 3 mm 120 A at most 0 8 mm at most 1 5 75 2 105 2 5 130 4 205 6 310 4 mm 160 A at most 1 0 mm at most 2 75 2 5 95 4 155 6 230 PRO 200 3 mm 120 A...

Страница 4: ...requency of voltage supplied to the transformer the transformer can be made several tenfolds smaller That is why weight and overall dimensions of this machine is several times smaller than those of re...

Страница 5: ...oltage reduction unit on off on off on off on off MMA open circuit voltage V 12 75 12 75 12 75 12 75 Arc striking voltage V 110 110 110 110 Rated power consumption kW 4 0 4 6 5 5 6 1 6 9 7 9 6 9 7 9 M...

Страница 6: ...n a manual metal arc welding with a stick electrode MMA b tungsten arc inert gas welding TIG c semiautomatic metal inert active gas welding MIG MAG 5 Machine operation indicator a permanent green ligh...

Страница 7: ...MAG welding with solid wire cable of the feeder machine is connected c in case of semiautomatic MIG MAG welding with flux wire earth cable is connected B Power current socket of bayonet type a in case...

Страница 8: ...3 4 hours Therefore do not switch the machine off in cold season if you are going to switch it on within 4 hours The machine must be placed to ensure free inlet and outlet of cooling air through vent...

Страница 9: ...LDING Procedure for machine preparation to operation insert the electrode cable into the source socket insert the earth cable into the source socket B connect the earth cable to the work piece connect...

Страница 10: ...be increased to maximum value for even better quality of the striking moment if the machine is operated from good power mains However keep in mind that boosted current of this function can burn throu...

Страница 11: ...n can also be increased to maximum value for even better stability of short arc burning but this requires for better supply mains and increases the risk of work piece burn through The result is achiev...

Страница 12: ...es 13 45 70 it is recommended although not required to set the slope CVS to 1 0V A On the other hand cellulose electrodes 1 4 even require for setting the slope CVS to 0 2 0 6V A and sometimes it is a...

Страница 13: ...t are set to most common values of 5 0 Hz and 50 respectively In order to enable this function it is enough to set pulsing power Po P to a value above zero This parameter is set in percent of current...

Страница 14: ...ct the earth cable to the work piece install pressure reducer on the gas bottle connect gas hose of the torch to pressure reducer of the gas bottle open the cock of the gas bottle and check it for tig...

Страница 15: ...f arc striking This function is implemented by touching the work piece with the element The user can keep the electrode in this position for an unlimited time and when he she decides that he she is re...

Страница 16: ...lsing frequency Fr P and mark to space ratio or duty ratio dut By default pulsing power Po P which is the key parameter is set to OFF position i e disabled while pulsing frequency Fr P and duty ratio...

Страница 17: ...nal wire feeding machine In order to do that it must have its own supply source or be supplied by the source voltage this option is less desirable because such systems rarely provide good and stable w...

Страница 18: ...see changeover sequence in paragraph 6 1 Control slot 8 on the rear panel provides control over switching the source on and off Connection diagram Contacts 1 and 2 are the only used contacts which ar...

Страница 19: ...specific application 5 1 WELDING CYCLE MIG MAG See paragraph 6 1 for sequence of changing parameters of functions Time of pre purging t1 and post purging t2 with shielding gas is set on the wire feed...

Страница 20: ...P which is the key parameter is set to OFF position i e disabled while pulsing frequency Fr P and duty ratio dut are set to most common values of 20 Hz and 50 respectively In order to enable this func...

Страница 21: ...of the main parameter of the current welding mode on its digital indicator 1 in MMA mode arc current 2 in TIG mode arc current 3 in MIG MAG arc voltage Buttons 3 on the front panel serve to change the...

Страница 22: ...formed for each mode individually It is designed this way for convenience so that the user does not reset customized settings of the remaining two modes 7 GENERAL LIST AND SEQUENCE OF FUNCTIONS MMA we...

Страница 23: ...ng power OFF by default a 0 OFF 80 increment 1 3 Fr P current pulsing frequency 10 0 Hz by default a 0 2 500 Hz dynamic increment 0 1 Hz 1 Hz 4 dut mark to space ratio duty ratio is the ratio of large...

Страница 24: ...plug Wait until internal circuits of the machine de energize about 5 minutes and only then proceed with other actions When leaving the machine install a restrictive plate which prohibits switching the...

Страница 25: ...50 60 Hz 220 V Mains voltage variation range 160 260 V Efficiency ratio at rated current 92 Arc current adjustment range 8 160 A 10 200 A 12 250 Arc current at 5 min 70 LD 5 min 100 LD 160 200 250 13...

Страница 26: ...g results in the following dangers injury of maintenance personnel or third persons damage of the machine or property of the enterprise derangement of efficient working process All persons dealing wit...

Страница 27: ...GER OF MAINS AND ARC CURRENT electric shock can lead to death magnetic fields created by this machine can have adverse effect on operability of electrical appliances such as cardiac pacemakers People...

Страница 28: ...le avoid installing the welding machine directly on the conductive coating of floor or work table use insulating pads SAFETY MEASURES IN NORMAL CONDITIONS Check the machine for external damages and pe...

Страница 29: ...27 PATON PRO series DC MMA TIG MIG MAG Schematic electrical diagram of the Source PATON PRO 160 200 250 DC MMA TIG MIG MAG 220VAC...

Страница 30: ...8 16 ACCEPTANCE CERTIFICATE Arc inverter rectifier PATON PRO 160 200 250 Serial number __________________________P has been approved for operation Sale date _____ _________________20____ Stamp here __...

Страница 31: ...__________ Date of receipt for repair _____ _________________20____ __________________ signature Symptoms of non operability ______________________________________ Cause ______________________________...

Отзывы: