66
Wall mount Signal Tower Instruction Manual
9. Maintenance
9. Maintenance
This product can be initialized in two methods. For information about the items that can be initialized, refer to the
table below.
Initialization Method
Change
language
Main unit
settings
Network
Settings
Command
Reception
Settings
Modbus/TCP
Password
Set button
●
●
●
●
●
●
Web Setup Screen
●
●
x
●
●
●
●
●
●
●
●
●
●
: Initialized items, X : Non-initialized Items
9.1.1. How to Initialize with the "Switch for Initialize"
The "Switch for Initialize" is located inside the cover. For details, refer to "4. Part Names and Dimensions" (
.
CAUTION
Do not press the "Switch for Initialize" too hard. Failure to follow this instruction could result in equipment damage.
Do not use excessive force operation on "Switch for Initialize". Failure to follow this instruction could result in deformed
frame and product damage.
Do not use sharp tipped objects with this product. Operation may become impossible as scratches develop on "Switch for
Initialize" and switch contacts are interfered with.
9.1.
Initialization Method
Remove the cover.
❶
Press the "Switch for Initialize" more than 3
seconds.
❷
Status lamp flashes.
❸
・
When the status lamp flashes, initialization is
complete. Stop pressing the "Switch for Initialize".
・
When the initialization is completed, the system
restarts with the factory defaults. For the contents
of each item setting in the factory default state,
refer to "
Initial values of each item after
initialization (factory default)" (
・
Press and hold the "Switch for Initialize" more
than 3 seconds using a non-conductive tool (e.g.,
ceramic screwdriver) with a diameter of about 2
mm.
→
Status lamp flash.
Main unit
Switch for Initialize
Status Lamp
Cover
Press more than 3 seconds
using ceramic screwdriver
Flashing
❶
❷
❸