7.1 WDB-D80S Installation
7.1.1 Installing and Removing WDB-D80S
7. Operation
NOTICE
●Requirements for the mounting location.
・
Minimal vibration
・
Strong
・
Level
●Install this product in the upright position.
●If you need to install on an uneven surface and waterproofing is required, use a sealant in the gap between the product
and mounting surface.
●For IP65 rating requirement, when clamping brackets to the mounting surface, apply sealant to the screw or nut portion
and the wire distribution hole.
●When using the RS-232C cable, fix it in place so it is not subjected to bending or pulling.
・
There are two wiring methods for the RS-232C cable, "Wiring RS-232C Cable from Bottom of Main Unit" and
"Wiring RS-232C Cable from Cable Gland".
・
The RS-232C cable is offered as an accessory (Part number WDX-SC01) but you can use any commercially
available product. Use a cable with lead wires that have a wire diameter of AWG24 to 28. When using the cable
gland wiring method, use a cable with a
φ
4.5 to 6.5 mm diameter.
*When providing your own, strip one end of the cable as shown below.
70 mm
The position of the mounting holes is different between using M4 bolts and M3 bolts.
( 単位:mm)
取付穴
( 3ヶ 所)
φ
4
φ
3
ガイド 円
φ
40
φ
30
ボルト
ナット
M4
M3
120°
Nameplate Location
Product Front
Product Outer Dimension
Wire Distribution Hole
(
φ
12)
120°
When using M4 bolts:
φ
40
When using M3 bolts:
φ
30
When using M4 bolts:
φ
4 (3 places)
When using M3 bolts:
φ
3 (3 places)
About the RS-232C Cable
Mounting Hole Dimension Diagram