24
Signal Tower LA6-POE Operation Manual
4.5. Main Unit Setup
The buzzer volume and the control method can be set up.
The LED unit setup data can be synchronized.
Item
Contents
Default Value
Input
Parameter
Setup
Option
Buzzer Sound
Select among 0 (Mute), 1, 2, and 3 (Maximum).
3 (Maximum)
-
×
Control-system
Switchover
Select among "Command Control" and "Signal
Wire Control".
Command
Control
-
×
* The "Setup Option" indication is explained below to indicate in the diagram whether a value input is omissible (a
blank is used) or not.
The "x" indicates where is not omissible, or is selected from an item menu.
MEMO
• When 0 (Mute) is set, the buzzer won't sound.
• When the command control method is selected, the LED unit can not be controlled by the
signal line input.
• When the signal line control method is selected, control can not be done by commands.
Only status acquisition and reboot is possible.
• Reboots automatically after the setup changes.
• Click ”Sync” button when writing setup data using usb cable.