NOTE: Terminate both ends of the wire identically, as per above (wall
station and gateway)
CC5 CC6 CC7 CC8 COM
CC1
CC2
CC3
CC4
COM
Rx+
Rx-
Tx-
Tx+
+24v
GND
Rx+
Rx-
Tx-
Tx+
+24v
GND
+24v
GND
EAR
TH
GND
+24v
SHLD COM
D-
D+
NC NC
SHLD
COM
D-
D+
NC
NC
DMX POR
T B
DMX
POR
T A
Rx+ Rx- Tx- Tx+ +24v
GND
Rx+ Rx- Tx- Tx+ +24v
GND
BUS 1
BUS 2
BUS 3
POWER
BUS 4
Power
DMX—B OUTPUT
DMX—B INPUT
DMX—A OUTPUT
DMX—A INPUT
Identify
Record Enable
1
2
3
4
5
6
7
8
DMX512/RDM Ports
(x2)
Contact Closure
Inputs (1-4)
Connector
Contact Closure
Inputs (5-8)
Connector
PWGW DIN V
Vignette Architectural Gateway
Installation
Guide
08.27.21
Pin 1: Rx+
Pin 2: Rx-
Pin 3: Tx-
Pin 4: Tx+
Pin 5: +24V
Pin 6: GND
NC:
NC:
White/Orange
Orange
Green
White/Green
Blue
Brown
White/Blue
White/Brown
Pin 1: Rx+
Pin 2: Rx-
Pin 3: Tx-
Pin 4: Tx+
Pin 5: +24V
Pin 6: GND
NC:
NC:
Black (White pair)
White
Green
Black (Green pair)
Red
Black (Red pair)
Shield foil
Drain wire
Vignette is an architectural DMX Snapshot Record and
Recall system consisting of wall stations and gateways.
Vignette’s Architectural Gateways provide connectivity for
the Vignette wall stations, DMX In used to capture scenes
from a programming console and DMX Out/Thu to your
lighting rig.
The gateway features terminal blocks that can be removed from the
module to facilitate wiring. Both compression screw and IDC terminal
blocks are supplied. Use IDC connectors with solid core cable and
compression screw with stranded copper wire.
POWER
The gateway must be supplied 24 VDC. If your system uses the full
64 insert capacity, you must supply 72 Watts.
DO NOT
use the IDC
connectors on the main power connector.
DMX
Connect the control source you want to snapshot to Port B. Observe
the same polarity convention throughout the system. Connect the
lighting system (LEDs, Dimmers, Interfaces etc.) to Port A.
STATION BUSES
All station bus wiring must be in a continuous run and daisy-chained.
No “tees” are permitted. Maximum cable length for category 5 wiring is
500 feet (152 meters). Maximum cable length for Belden 9773 wiring is
1000 feet (305 meters). The last station on the line must be terminated
with two resistors with a value of 100 to 120 ohms, between pins 1 &
2 and between pins 3 & 4. Architectural Gateways ship with four pre-
terminated IDC connectors.
Each bus can power up to 16 inserts. For example, a wall station
comprising of one 4-button master and a dual slider slave counts as
2 inserts. The gateway can power a total of 64 inserts across the four
buses. There is no addressing logic per bus; by default, button 1 on all
stations is snapshot #1, etc. Advanced wall station configuration must
be done over an Ethernet network link with Pathscape running on a PC.
CONTACT CLOSURES
Dry contact closure terminals are provided on gateway model PWGW
DIN VD2C8, VE2C8 and VC16 (8, 8, and 16, respectively) for triggering
memories with external momentary contacts. Buttons with LED
indicators are included on the gateway itself for local control or testing
purposes.
OVERVIEW
STATION BUS WIRING
CONNECTIONS
STATUS INDICATORS
Category 5 Wiring
(using IDC connector)
Belden 9773 Wiring (using
compresson screw)
POWER
Glowing steadily red indicates power supply is OK;
off indicates no power.
IDENTIFY
Will flash blue when Pathscape software is
identifying the gateway. Without Pathscape
connected, you will not see this indicator light on.
RECORD
ENABLE
When this function is activated by the button, the
LED will glow red. If you press and hold a button for
5s on a wallstation you will snapshot the incoming
DMX512 for recall from that button.
BUS
Bus lights will flash red when the gateway receives
data from the inserts on the bus. Likewise, the Link
LED on the back of the master inserts will blink
when they receive data from the gateway.
DMX INPUT/
OUTPUT
(A/B)
DMX A and B each have an amber LED when the
port is configured as an input. If no DMX is present,
the amber LED will flash. DMX Output LEDs are
solid green when active. The LED will flash if no
eDMX is present and the port is inactive.
RJ45 LEDs
The RJ45 Ethernet jack has two green LEDs. One
will glow steady when the link is up and the other
will flash with activity.
CONTACT
CLOSURE
LEDs
These will mirror existing button/slider
configurations. These LEDs will also flash when
Pathscape is identifying the gateway.