The two PWR LEDs on the Installation 

Repeater will illuminate when AC power is 
connected to the unit. There is no on/off 
switch. 

The two DATA LEDs will illuminate and 

flicker rapidly to indicate that DMX data is 
being received.  

Two TEST indicators are associated with 

the DMX input and each of the six outputs. 
Refer to the 

Cable Test Feature 

instruc-

tions. 

Indicators 

Power  
Supply:

 

Universal input (90-250V, 
50/60Hz), 0.2A 

Isolation:

 

2500V Opto-isolation on DMX lines 
4000V Mains isolation 

Protection: 

Up to 250VAC/DC on all  
port pins 

Protocols:

 

DMX512 , DMX512-A, or any EIA422 
or 485 based simplex protocol 

Size: 

19 x 10 x 3in. (483 x 254 x 76 mm) 

Specifications 

DMX512-A Compliance 

The Pathway Installation repeater is com-

pliant with DMX512-A under the non-
compatible connector (NCC) provision. 

All ports are DMX512-A protected to 

250V with self-healing circuitry. 

Subject to change without notice   

103 Inglewood Plaza 1439 17Avenue SE  Calgary AB, Canada T2G 1J9 • +1 403 243-8110   Fax +1 403  287-1281 

Printed in Canada R8 

D - 

ON 

Data present on 

D +  ON 

incoming DMX line 

D - 

OFF 

D- signal missing  

D +  ON 

  or shorted to common 

D - 

ON 

D+  signal missing  

D +  OFF 

or shorted to common 

D - 

OFF 

No data present on incoming  

D +  OFF 

DMX line 

via the input connection, as per the previ-
ous instructions. Once that is verified, dis-
connect the cable to the suspect output 
channel and depress the corresponding 
ISO OUT TEST button. If both the corre-
sponding D- and D+ LEDs illuminate, this 
shows that the isolated output circuitry 
inside the repeater is working properly and 
is transmitting both DMX512 signals. If 
not, there is likely a problem with the out-
put circuitry for that channel. Try using the 
spare transceiver chip to remedy the prob-
lem. Now reconnect the cable to the sus-
pect output and perform the same test. If 
both of the D- and D+ LEDs illuminate, this 
shows that there are no shorts in the out-
put cabling or connected receiving de-
vices. If one or both of the LEDs is off or 
dim, a cable or device problem is indi-
cated. NOTE: if an output TEST button is 
pushed when a proper input signal is not 
being received by the Installation Re-
peater, the outputs will be in their normal 
“idle” state (i.e. D- low level, D+ high 
level), therefore the D+ LED will illuminate 
and the D- LED will not. 

INPUT TEST  

INDICATIONS

 

Cable Test Feature 

cont.

 

4802 Installation Repeater 

6-way opto-isolated DMX splitter

 

To ensure trouble free operation, DMX512 
standards require that DMX devices be 
installed in a daisy chain, with no tees, 
wyes or stars in the DMX wiring. However, 
site conditions may make star wiring 
desirable or even mandatory. A Pathway 
DMX Repeater permits star wiring by 
making each branch of the star function 
electrically as its own entity, unaffected by 
the other branches of the star. 
Additionally, opto-isolation circuitry 
isolates each branch to prevent ground 
loops or accidental damage from fault 
voltages on DMX lines. 

Operational Philosophy 

• 

All cabling must be in a continuous run, 
daisy-chained, no “Tees” allowed 

• 

“Stars” are permitted only in conjunction 
with a repeater 

• 

Cable shield may be earth-grounded at 
one end only, preferably at the control 
console 

• 

Maximum length of one cable segment 
is 1,800 ft. (550m) 

• 

Recei ving devices  have mal e 
connectors, transmitters have female 

• 

The last DMX device on the line must be 
terminated with a termination switch or 
resistor with a value of 100 to 120 ohms

 

between pins 2 and 3. 

• 

5 pin XLR type DMX connectors are 
standard: 

   

Pin 1: 

Common

 

  

Pin 2: 

Data (-)

 

  

Pin 3: 

Data (+)

 

  

Pin 4: 

Optional Data (-)  

 

Pin 5: 

Optional Data (+)

 

• 

Cable must be  Belden 9842 (120

Ω

), 

9829, 9729 (100

Ω), 

ISO/IEC 11801 

(Cat5) 

 

or equivalent 

• 

A maximum of 32 DMX receiving 
devices can be present on a single DMX 
line 

DMX Wiring 

I

NSTALLER

S

 

G

UIDE

 

4802 Installation Repeater 

6-way opto-isolated DMX splitter

 

Mounting 

Installation Repeaters are designed for 

indoor use, in a dry location. Mount the 
Installation Repeater with appropriate fas-
teners to the wall.  Run conduit into the 
box through the knockouts provided, en-
suring that line voltage wiring is kept inside 
the barriered power supply section. 

An essential component of any 
DMX512 distribution system, the 
Installation Repeater permits star 
wiring installations while isolating 
a n d   p r o t e c t i n g   c o n n e c t e d 
equipment from harmful electrical 
f aul t s.  P athw ay In st all atio n 
Repeaters feature self-healing 
protection devices on all ports to 
prevent internal damage when 
severe faults of up to 250V are 
accidentally applied to the 
connected DMX cabling. To help 
you resolve any cable, signal or 
component issues fast, there are 
useful test functions built right into 
the product. 