pass & seymour RWU600B Скачать руководство пользователя страница 1

In

st

al

la

tio

n

In

st

ru

ct

io

n

s

Please read all instructions before installing

Visit our website at: www.passandseymour.com

RWU600B

Vacancy Sensor Switch

with Manual

ON/OFF   

SPECIFICATIONS

Voltage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .120VAC, 60Hz
Load (Single Pole Circuit)

Incandescent or fluorescent light  . . . . . . . . . . . 0-600 Watt 
Fan motor  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/6 hp

Time Delay  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 minutes
Environment . . . . . . . . . . . . . . . . . . . . . . . . . . . .Indoor use only

Operating Temperature . . . . . . . .32° to 131°F (0° to 55°C)
Humidity . . . . . . . . . . . . . . . . . . . .95% RH, non-condensing

Tools Needed:

Insulated Screwdriver
Wire Strippers

Lens

ON/OFF button
with pilot light

TROUBLESHOOTING 

To test the detection coverage:

During the TEST mode, the controlled load turns ON for 5 seconds each time the
sensor detects occupancy. 
1. Press and hold the ON/OFF button. After 10 seconds the pilot light flashes.

The load turns ON if it was not already ON. The sensor is now in a TEST mode
that lasts 5 minutes. (You can end the TEST mode sooner by pressing the
ON/OFF button for another 10 seconds). 

2. Move out of the coverage area or stand very still. The controlled load turns

OFF after 5 seconds, if no motion is detected. 

3. Move in the coverage area. The pilot light flashes each time the sensor

detects motion and the controlled load turns ON for 5 seconds. 
After 5 seconds expire without motion detection, the load turns OFF. 
The load turns ON automatically with the next motion detection and stays on
for 5 seconds. 

4. Repeat as necessary to ensure that the desired coverage areas are within

detection range. 

Load will not turn ON (pilot light is visible):

Press ON/OFF button. The load should turn ON. If not:
• Check the light bulb and/or motor switch on the fan mechanism.
• Turn off power to the circuit then check wire connections.

Load will not turn ON (pilot light is NOT visible): 

• Check the light bulb and/or motor switch on the fan mechanism.
• Make certain that the circuit breaker is on and functioning.
• Turn off power to the circuit then check wire connections. 
• Call 800.223.4185 for technical support. 

Load will not turn OFF:

• Make sure no motion is occurring in the coverage area until the 30 minute

time delay expires. 

• Hot air currents and heat radiating devices can cause false detection. Make

sure the sensor is at least 6 feet (2 meters) away from devices that are a
significant heat source (e.g., heater, heater vent, high wattage light bulb).

• Press the ON/OFF button. If load does not turn off, turn off power to the

circuit then check wire connections.

P.O. Box 4822, Syracuse, NY 13221-4822

Technical Support: 800.223.4185 • www.passandseymour.com

340801 Rev. B 08130

Limited FIVE YEAR Warranty

Pass & Seymour/Legrand will remedy any defect in workmanship or material in Pass & Seymour/Legrand
products which may develop under proper and normal use within five years from the date of purchase by a
consumer:

(1) by repair or replacement, or, at Pass & Seymour/Legrand’s option, (2) by return of an amount equal to the
consumer’s purchase price. Such remedy is IN LIEU OF ANY AND ALL EXPRESSED OR IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Such remedy by Pass & Seymour/Legrand does 
not include or cover cost of labor for removal or reinstallation of the product. ALL OTHER FURTHER ELEMENTS
OF DAMAGE (INCIDENTAL OR CONSEQUENTIAL DAMAGES) FOR BREACH OF ANY AND ALL EXPRESSED OR
IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE ARE EXCLUDED HEREBY. (Some states do not allow disclaimer or exclusion or limitation of incidental
or consequential damages, so the above disclaimers and limitation or exclusion may not apply to you.) ANY
IMPLIED WARRANTIES INCLUDING WHERE REQUIRED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR 
A PARTICULAR PURPOSE SHALL BE LIMITED TO THE FIVE YEAR PERIOD SET FORTH ABOVE. (Some states do
not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.)

To ensure safety, all repairs to Pass & Seymour/Legrand products must be made by Pass & Seymour/Legrand or
under its specific direction. Procedure to obtain performance of any warranty obligation is as follows: (1) Contact
Pass & Seymour/Legrand, P.O. Box 4822, Syracuse, NY 13221 for instructions concerning return or repair; 
2) return the product to Pass & Seymour/Legrand, postage paid, with your name and address and a written
description of the installation or use of the Pass & Seymour/Legrand product, and the observed defects or failure
to operate, or other claimed basis for dissatisfaction.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

340801RevB_Eng  8/27/07  10:34 AM  Page 2

Отзывы: