Please read all instructions before installing

DESCRIPTION AND OPERATION

The RWDU500 Multi-way Dimming Wall Switch Vacancy Sensor is designed to 

replace a standard single pole or multi-way (3-way, 4-way) switch or dimmer. It 

is ideal for living and dining rooms, family rooms, bedrooms, bathrooms and any 

other indoor area in a residential space where occupancy sensor-based manual 

ON/OFF and Dimming control is desirable.
Like a standard switch, you press the ON/OFF/DIM button to turn the dimmable 

lighting load ON and OFF. Unlike a standard switch, the RWDU500 automatically 

turns OFF the controlled load after the coverage area has been vacant for a period 

of time (Time Delay). If motion is detected within 30 seconds after it automatically 

turns OFF, the RWDU500 automatically turns the load back ON. Like a standard 

dimmer, once the lighting load is ON, you can dim it UP or DOWN by pushing and 

holding the ON/OFF/DIM button. When you push the ON/OFF/DIM button to turn 

the dimmable load ON, the RWDU500 recalls the last used dimming level.
While the sensor is factory preset as a Vacancy Sensor with manual ON operation, 

it can be adjusted to work as an Occupancy Sensor that turns the controlled load 

ON automatically upon detection of occupancy in the area.
The RWDU500 can be wired with up to 3 additional RWDU500s for multi-way 

Manual/Auto –ON/OFF of one or several loads (up to one load connected to each 

RWDU500). It can also be wired to up to 4 TM870STM single pole momentary wall 

switches for multi-way Manual-ON/OFF Automatic-OFF control of one load. 

RWDU500 

Multi-way Dimming Wall Switch

 Vacancy Sensor

with Manual ON/OFF/DIM 

Lens

Lighted Switch  

ON/OFF/DIM button 

SPECIFICATIONS

Voltage  ...............................................................120VAC, 60Hz

Load (Single Pole Circuit)  ......................................25-500 Watt

Compatibility ........................................................Incandescent

Time Delay Adjustment  ...................15 seconds to 30 minutes

Light Level Adjustment  ......................................10 fc to 150 fc

Environment  .................................Residential Indoor use only

Operating Temperature   ................... 32° to 104°F (0° to 40°C)

Humidity  .......................................... 95% RH, non-condensing

Electrical Supply Wire Requirement

Minimum temperature rating ...............................75°C (167°F)

Tools Needed  ............... Insulated Screwdriver, Wire Strippers

Syracuse, NY 13221-4822

Call 800.223.4185 for Technical Support

Air Gap Isolation Switch

Time Delay

The time delay can be selected by the user during set up. It can be adjusted to 

any of these fixed values:15 seconds/5 minutes/15 minutes/30 minutes. It is 

recommended to set all of the sensors related to the same load to the same time 

delay to ease understanding of the multi-way control operation as well as trouble 

shooting. For additional information on how to adjust it, please read the SENSOR 

ADJUSTMENT & PROGRAMMING section of this installation manual.

Light Level

When the operating mode is set for occupancy sensor, Mode 2 (Auto-ON) this 

feature prevents the sensor from automatically turning the lights ON if there is 

already enough light in the area.
In a multi-way application with various RWDU500s, each sensor monitors the 

light level at its location. If any sensor related to the load detects motion AND 

the measured light level in that sensor’s area is lower than its Light Level 

setting, the load turns ON. To adjust the light level, please read the SENSOR 

ADJUSTMENT & PROGRAMMING section of this installation manual.

Coverage Area

The RWDU500 has a maximum range of 180 degrees  

and a coverage area of 600 sq. feet (56 sq. meters).  

The sensor must have a clear and unobstructed  

view of the coverage area. Objects blocking the  

sensor’s lens may prevent detection thereby  

causing the light to turn OFF even though  

someone is in the area.

Windows, glass doors, and other 

transparent barriers will obstruct the 

sensor’s view and prevent detection.

Lighted Switch

To help you locate the RWDU500 in a dark room, the green LED illuminates the 

ON/OFF/DIM button while the controlled load is OFF. When the controlled load is 

ON, the LED is OFF.
The lighted switch ON/OFF/DIM button can be used to manually turn ON and OFF 

the lighting load and to dim it UP and DOWN. 
To turn the load ON, tap firmly on the ON/OFF/DIM button once. The green LED 

turns OFF and the load turns ON to the last used dimming level. The lighting load 

may or may not appear to be ON depending on how low the lights were set the 

last time they were dimmed. 
Once the load has been turned ON, push and hold the ON/OFF/DIM button to dim 

the lights UP or DOWN. To reverse the dimming direction momentarily release 

the ON/OFF/DIM button, then push and hold it again. This feature will allow you to 

reach the desired dimming level quicker.

OPERATINg MODES

For multi-way operation of two or more RWDU500s, it is recommended to set 

the Operating Mode to be the same in all sensors related to the same load. This 

recommendation will ease understanding of the multi-way control as well as 

trouble shooting. There are two operating modes to select from:

MODE 1

  Vacancy sensor (Manual-ON/OFF, Auto-OFF): The user must press 

(tap) the ON/OFF/DIM button to turn the load ON. The RWDU500 keeps the load 

ON until no motion is detected by any of the related RWDU500s for the time 

delay period. There is also a 30 second reset delay after the automatic shut-

off. If motion is detected during this time, the sensor turns the load back on 

automatically. After the 30 second reset delay has elapsed, the ON/OFF/DIM 

button must be pressed to turn ON the load.

MODE 2 

Occupancy sensor (Auto-ON/OFF with manual control and reset to auto 

after 5 minutes of vacancy): The load turns ON and OFF automatically based on 

occupancy detection. Once turned ON the RWDU500 keeps the load ON until no 

motion is detected by any of the related RWDU500s for the time delay period. If 

the load is turned OFF manually, automatic-ON is re-enabled when no motion is 

detected for 5 minutes. This prevents the load from being turned on after it was 

deliberately turned OFF.

www.passandseymour.com

INSTALLATION & WIRINg

These instructions describe single pole, 3-way and multi-way circuit applications.
If you are unable to clearly identify some or all of the wires identified in step 2 of 

the instructions, you should consult with a qualified electrician.
Steps 4a, 4b, and 4c describe each circuit application.
For information about other applications, consult technical support or the  

Pass & Seymour website. 

1.  Prepare the switch box.

   After the power is turned OFF at the circuit  

breaker box, remove the existing wall plate and  

mounting screws. Pull the old switch out from  

the wall box. 

2.  Identify the type of circuit.

   You may connect the RWDU500 to a single pole  

(see Fig. 2) or 3-way circuit (see Fig. 2a). 

   In a 3-way circuit, two traveler wires connect  

to both switches. Another wire provides power  

from the circuit box to one of the switches. A wire  

connects from one switch to the load. A ground  

wire may also be connected to a ground terminal  

on the old switches. A neutral wire should also be  

present in both wall boxes.

3.   Prepare the Wires. 

Tag the wires currently connected to the existing 

switch so that they can be identified later. 

Disconnect the wires. Make sure the insulation 

is stripped off of the wires to expose their copper 

cores to the length indicated by the “Strip Gage,” 

in Fig. 3. (approx. 1/2 inch).

For your safety: Connecting a proper ground to the sensor 

provides protection against electrical shock in the event of certain 

fault conditions. If a proper ground is not available, consult with 

a qualified electrician before continuing installation.

*URXQG

+27SRZHUIURP

FLUFXLWER[

/2$'

SRZHU

WRODPS

1(875$/

Fig. 2:  Typical Single 

Pole Switch

Green 

->

 GROUND

Black 

->

 HOT (power

from circuit box)

White 

->

 

        NEUTRAL

Red 

->

 LOAD (power

to dimmable lamp)

Yellow 

->

  CAP (Traveler,

 

 

not used for

 

 

single pole)

Fig. 4a:   Sensor orientation, single pole wire 

connections and wall box assembly

Strip Gage

1/2"

12.7 mm

Fig. 3:  Wire Stripping

4a:  Single pole wiring:

  Twist the existing wires 

together with the wire  

leads on the RWDU500  

sensor as indicated below. 

Cap them securely using  

the wire nuts provided  

(See Fig 4a).

•  Connect the green or 

non-insulated (copper) 

GROUND wire from the 

circuit to the green wire on 

the RWDU500.

•  Connect the NEUTRAL wire 

from the circuit and from 

the lamp (LOAD) to the white 

wire on the RWDU500.

•  Connect the power wire 

 

from the circuit box (HOT) to  

the black wire on the RWDU500.

•  Connect the power wire to the 

 

lamp (LOAD) to the red wire on the RWDU500.

•  Cap the yellow wire on the RWDU500. It is not used in single pole applications.

4b:  3-way wiring using two RWDU500s:

  Twist the existing wires together with the wire leads on the RWDU500 sensors 

as indicated below. Cap them securely using wire nuts provided. (See Fig. 4b)

•  Connect the green or non-insulated (copper) GROUND wire from the circuit to 

the green wire on the RWDU500.

•  Connect the NEUTRAL wire from the circuit and from the lamp (LOAD) to the 

white wire on the master RWDU500.

  The term “master” designates the RWDU500 that connects to the load.

•  Connect the NEUTRAL wire from the circuit in the other wiring box to the white 

wire on the auxiliary RWDU500.

•  Connect the power wire from the circuit box (HOT) to the black wire on the 

auxiliary RWDU500 and to the TRAVELER 1 wire.

•  Connect the TRAVELER 1 wire from the black wire of the auxiliary RWDU500 to 

the black wire of the master RWDU500.

•  Connect the lamp power (LOAD) to the red wire on the master RWDU500.
•  Cap the red wire on the auxiliary RWDU500.
•  Connect the TRAVELER 2 wire coming from the yellow wire of another 

RWDU500 to the yellow wire of the RWDU500 that you are wiring.

AUXILIARY RWDU500

MASTER RWDU500

Red

Ground

Yellow

Black

White

Red

Ground

Yellow

Black

White

Load

Traveler 1

Traveler 2

Neutral

Hot

Neutral

Fig. 4b:  Reference wiring diagram, 3-way using two RWDU500s

25'

(7.6m)

12'

(3.7m)

Fig. 1: Sensor Coverage Area

CAUTION  —  WARNINg

To reduce the risk of overheating and possible damage 

to other equipment, do not install to control a receptacle, 

a motor-operated appliance, a fluorescent lighting 

fixture, or a transformer-supplied appliance. 

Disconnect power to the wall switch box by turning OFF  

the circuit breaker or removing the fuse for the circuit before installing 

the RWDU500, replacing lamps, or doing any electrical work.

Call 800.223.4185 for Technical Support

www.passandseymour.com

Fig. 2a:  Typical 3-way Switch Wiring

NEUTRAL

GROUND

LOAD/Common

(power to lamp)

NEUTRAL

GROUND

          HOT/Common

(power from circuit box)

TRAVELER

TRAVELER

Lamp/load

MASTER SWITCH

AUXILIARY SWITCH

340898 11049_RWDU500 IS.indd   1-4

9/3/09   10:34 AM