40
Cantinola Touch 2016 operating and maintenance manual
Operation of maintenance to be carried out by a qualified technician
-
Every 6 months
•
Inside/outside cleaning of the chimney
•
To clean accurately the brazier and its compartment
•
Inspection, cleaning and descaling of the ignition coil and its compartment
•
To clean of the display and remote control
•
To clean the pellet tank and the rotary valve
•
Functional testing of ignition and loading
•
To clean the fan extractor after taking out the ash drawer.
-
Every year
(in addition to the up above 6-month maintenance)
•
To replace the ignition cartridge when with 3 ignitions per day.
•
Inspection of the electrical cables, connections e power cable.
•
Checking the water connections and sealing
•
Inspection and cleaning of smoke channels
•
Chimney draught control and cleaning
In addition, to clean the case of the boiler’s smokes
To vacuum the soot that has been deposited on the flat parts
of the smoke rounds.
Important
Any extra maintenance which may be required, must be carried out only by the
manufacturer, by an authorised service agent or by a qualified technician using
only original spare parts. On the contrary, all the warranty conditions will be not valid.