INSTRUCTION REF: IN123
ISSUE No. 3
DATE 17.08.15
Page 3 of 15
www.parry.co.uk
INSTALLATION
1.
Choose a suitable site for your machine taking into consideration its, use, and
any heat that may be generated whilst in service.
2.
Remove all protect film and packing material, and inspect for any damage
which may
effect the machine’s electrical safety.
3.
Please find enclosed 4 x shelf adhesive rubber feet. There are 4 dimples on
the base of the unit where each foot must be placed.
4.
All appliances with an electrical loading above 3 kilowatts must be connected
to a suitable supply by qualified electrician, who should ensure that
a)
Precaution is taken during installation regarding leakage current,
b)
The means of isolation has a contact separation of at least 3mm on all
poles, and
c)
It is installed in accordance with Health and Safety at Work Act, BS
Codes of Practice, IEE Wiring Regulations and Building and Local
Authority Standards.
PARAGON FRYERS
OIL CAPACITY
–
PF6 & PF9 - 11 LITRES, ALL OTHER MODELS 6.1 LITRES PER PAN
POWER SUPPLY
–
PSF3 & PDF3 (X2) ARE FITTED WITH A 13 AMP 3 PIN PLUG
ALL OTHER MODELS MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN.
PSF6, PF6, PSPF6, PDF6 (X2), PDPF6 (X2)
– 25A 1~ 240V
8.5A 3~ &N 415V
PSF9, PF9, PSPF9, PDF9 (X2), PDPF9 (X2) - 37.5A 1~ 240V
12.5A 3~ &N 415V