Содержание HOT12

Страница 1: ...Instruction Manual Heated and Ambient Cabinets HOT12 HOT15 HOT18 HOT12P HOT15P HOT18P HOT12BM HOT15BM HOT18BM HOT121 2BM HOT151 2BM HOT181 2BM AMB12 AMB15 AMB18 AMB12P AMB15P AMB18P...

Страница 2: ......

Страница 3: ...erating Instructions 10 Cleaning Instructions 11 Maintenance Instructions 12 Fault Finding 13 Service Information 14 Wiring Diagram 15 16 Exploded View 17 18 Parts List 19 21 Warranty Information 22 D...

Страница 4: ...dors This unit can be used to create a counter between front of house and back kitchens with meals taken from sliding doors either side of the unit HOT12BM HOT15BM HOT18BM Ideal for care homes restaur...

Страница 5: ...ead the industry in Design and aesthetic appeal Performance Power Functionality After sales support HOT12 HOT15 HOT18 HOT12P HOT15P HOT18P Features HOT12 HOT12P HOT15 HOT15P HOT18 HOT18P Unpacked weig...

Страница 6: ...148 5 Dimensions w x d x h mm including handles 1200 x 650 x 900 1500 x 650 x 900 1800 x 650 x 900 No of plated meals based on 9 inch plate 72 90 108 Number of shelves 2 shelves 1 adjustable Cupboard...

Страница 7: ...kg 99 5 143 148 5 Dimensions w x d x h mm including handles 1200 x 650 x 900 1500 x 650 x 900 1800 x 650 x 900 No of plated meals based on 9 inch plate 72 90 108 Number of shelves 2 shelves 1 adjustab...

Страница 8: ...AMB12P AMB15 AMB15P AMB18 AMB18P Unpacked weight kg 79 5 123 128 5 Packed Weight kg 99 5 143 148 5 Dimensions w x d x h mm including handles 1200 x 650 x 900 1500 x 650 x 900 1800 x 650 x 900 No of p...

Страница 9: ...ORDANCE WITH CURRENT REGULATIONS The unit should be installed in compliance with the INSTALLATION INSTRUCTIONS and the NATIONAL REGULATIONS in force at the time Particular attention should be paid to...

Страница 10: ...items and installation instructions Push Handle Part Code PUSHHANDLE Rivnuts are fitted to both ends of the cabinet Align handle holes with the side of cabinet Affix the handle with the screws provid...

Страница 11: ...llowing depths 250 300 350 and 400mm with single up to three tiers Also can be lit or ambient options using the GL lightboxes For available sizes please check out our website www parry co uk and searc...

Страница 12: ...will be repeated automatically as the thermostat maintains a constant temperature The cabinet temperature is shown on the digital display on the fascia When loading the machine please leave some spac...

Страница 13: ...handle on the door and supporting the other side of the door lift the door upward until the bottom of the door clears the bottom rail of the cabinet Then tilt the door so the bottom of the door comes...

Страница 14: ...ervice must only be undertaken by a qualified electrician Parry Catering provides a complete after sales service by offering the sales of spare parts directly to customers Buying spares straight from...

Страница 15: ...ck unit is plugged into mains supply and the socket is switched on 2 Check the fuse in the plug 3 Try a different socket 4 If the unit has been permanently connected to a fused switch ask a qualified...

Страница 16: ...person Enhanced 2 Years Warranty Parry Catering Midlands Ltd offer an enhanced warranty of two years including parts and labour on all of the Parry manufactured products To take advantage of this you...

Страница 17: ...Parry British Built for Purpose IN133 7 15 Wiring Diagram Models HOT12 HOT15 HOT18 HOT12P HOT 15P HOT18P Models HOT12BM HOT121 2BM...

Страница 18: ...Parry British Built for Purpose IN133 7 16 Wiring Diagram Models HOT15BM HOT18BM HOT151 2BM HOT181 2BM...

Страница 19: ...Parry British Built for Purpose IN133 7 17 Exploded View HOT Range AMB Range inc Passthrough HOT12 Exploded View Used...

Страница 20: ...Parry British Built for Purpose IN133 7 18 Exploded View HOT BM HOT BM Range HOT12BM Exploded View Used...

Страница 21: ...AMB models 8 Cable Gland GLAND0M16 Not required on AMB models 8a Cable Gland Nut LOCKNTM16 Not required on AMB models 9 Unbraked Castor CASTOR100SHD 10 Cabinet No Code No Code No Code 11 Wire Guard No...

Страница 22: ...ck TB3POLETB HOT15BM TB6POLETB HOT151 2BM TB3POLETB HOT18BM TB6POLETB HOT181 2BM TB3POLETB 9 Cable Gland GLAND0M16 9a Cable Gland Nut LOCKNTM16 10 Unbraked Castor CASTOR100SHD 11 Cabinet No Code No Co...

Страница 23: ...umber Description HOT12 AMB12 HOT15 AMB15 HOT18 AMB18 25 15mm Olive OLIVE0015 26 Drain Valve VALVELB12 27 Drain Vale Plug PLUGBSP12 28 Handle Sleeve HANDLESLEEVE 29 Drain Vale Lever LCB00041 30 BSP Ma...

Страница 24: ...llation date of the equipment To be eligible for a 2 year warranty products must be serviced at least once within the first 12 months of purchase All service calls will be carried out between 8am and...

Страница 25: ...where you purchased the product Parry Catering recognises our obligations to the EU DIRECTIVE covering the waste disposal of electrical and electronic equipment WEEE Parry Catering are committed to t...