Replacement Parts
INST REF:IN274-3
DATE: 09/07/19
19
Replacement Parts
PILOT JET AND ELECTRODE
Undo pilot feed from gas valve, undo thermocouple from valve, remove screw from pilot
bracket, pilot assembly, c/w thermocouple and ignitor can now be removed.
THERMOCOUPLE
Undo thermocouple from gas valve; release probe end from the bracket on the pilot
assembly. Fit new in reverse order.
CONTROL THERMOSTAT
1) Drain fryer
2) Remove screws from mounting bracket
3) Remove the thermostat gland nut
4) Release thermostat phial from clip inside tank
5) Pull stat through tank, there will be some resistance felt due to the packing gland
being compacted.
6) Re-assemble in reverse order
7) Calibration of the thermostat where necessary is made by the screw in the centre
of the thermostat spindle. Clockwise to decrease temperature. Anti-clockwise to
increase.
CONTROL VALVE
1) Disconnect the gas supply pipe work and pipe to burners.
2) See previous notes for removal of pilot/thermocouple assembly, also thermostat
assembly.
3) Remove screws securing valve to bracket.
4) Remove fittings from valve to fit into replacement valves, as these are not
supplied with new valve.
5) Refit in reverse order.
SAFETY THERMOSTAT
1) Drain fryer
2) Remove spade connections on thermostat
3) Remove the two screws securing thermostat to bracket
4) Undo the gland nut on the tank and withdraw thermostat phial from bracket,
through the wall of the tank.
5) Fit new thermostat in reverse order.
Disposal and Recycling
Disposal and Recycling
The packaging should be disposed of in accordance with the regulations in force.