background image

      Parts List 

 

 

 

INST REF:IN274-3 

DATE: 09/07/19 

18

 

29 

*LH Door Assembly 

*NO CODE 

 

 

 

Burner Assembly

 

 

Part Number  

Description 

Code 

15mm x 3/8 BSPT  

GDF15ADAPT 

1a 

15mm – 12mm Reducing Set 

REDS1512F 

8mm x ¼ Tapper Compression 

Coupling 

COUPLE8MM 

Manifold Strap 

(Part of MANIFOLD1)

 

  

Injector Manifold 

MANIFOLD1 

Burner Injector 

NAT Gas = INJECT0230 
LPG Gas =  INJECT0160 

Over Temperature Thermostat 

TMST07000 

Burner 

BURNR7000 

Universal Thermocouple 

THCP900MM 

Pilot Assembly cw Electrode 

PILOT7000 

10 

Pilot Injector 

NAT Gas = PINJ76378 
LPG Gas = PINJ76371 

11 

*Pilot Bracket 

*NO CODE 

12 

*Burner Carriage 

*NO CODE 

13 

GV30 Gas Valve 

VALVEGDSF 

14 

8mm x 3/8 BSPT 

GDFSADAPT 

15 

6mm Pilot Shear Nut  

VALVEGDFFITT 

16 

Interrupter 

VALVETHCINT 

16a 

Interrupter Lead  

GDSFINTLEAD 

17 

6mm Pilot Pipe 

PIPE7000P-MM 

18 

8mm Burner Pipe 

PIPE7000B-MM 

 

GV30 Gas valve Blanking Plugs 

VALVEGDFPLUG 

 

 

Содержание GDF

Страница 1: ...Instruction Manual Model GDF GDFP Double Pedestal Gas Fryer...

Страница 2: ...quirements With over 40 years experience in commercial catering our equipment heats quickly cooks beautifully and cleans easily From food display units with specialist lighting to bespoke cupboard des...

Страница 3: ...ety Instructions 5 Installation Instructions 6 Technical Data 7 Operation Instructions 8 Maintenance Instructions 12 Cleaning Instructions 13 Fault Finding 14 Service Information 15 Exploded View 16 P...

Страница 4: ...SP Female GAS INPUT PRESSURE Natural GAS INPUT PRESSURE Propane 20 mbar 37mbar Can be converted using conversion kit Yes The Parry GDF gas double pedestal fryer is the ideal choice for commercial cate...

Страница 5: ...the rules in force Read the user instructions read the installation instructions and ensure the correct ventilation requirements are met Attention should also be drawn to the need for regular servicin...

Страница 6: ...training cable Gas hoses used to connect the appliance to the gas supply must be of the correct specification for the gas and pressure of the appliance The gas hose must comply with the national requi...

Страница 7: ...L GAS G20 20mbar 19 05 kW 2 02 M3 hr PROPANE GAS G31 37mbar 20 97 kW 0 86 M3 hr GAS INJECTOR PILOT INJECTORS NATURAL GAS G20 20mbar INJECT0230 PINJ76378 PROPANE GAS G31 37mbar INJECT0160 PINJ76371 GAS...

Страница 8: ...ry user of this and to ensure the user wears any necessary protective clothing when operating the fryer LIGHTING INSTRUCTIONS WARNING DO NOT LIGHT BURNERS WHEN THE PAN IS EMPTY 1 Open the compartment...

Страница 9: ...knob clockwise to the off position and turn off gas supply USE OF SOLIDIFIED OIL OR FAT 1 In an empty pan IMPORTANT If solidified oil or fat is to be used remove the grid from the bottom of the pan b...

Страница 10: ...ined at the level indicated Good quality vegetable oil is recommended The life expectancy of oils will be lengthened if they are filtered regularly food particles not removed turn rancid and reduce oi...

Страница 11: ...175 C Fritters 3 4 mins 175 C Potato Chips 2 mins 190 C Scampi 3 4 mins 175 C Temperature Settings STAT No Temperature 1 120 C 2 135 C 3 145 C 4 160 C 5 175 C 6 185 C 7 195 C ALL THE ABOVE ARE 5 C To...

Страница 12: ...perature and can cause overheating of the oil Fryers should never be left unattended Oil should not be added or drained from the unit while the unit is hot The appliance should be turned off and left...

Страница 13: ...long the life of the oil CLEANING INSTRUCTIONS The appliance should be cleaned with hot water and a mild detergent DO NOT USE ABRASIVES 1 Isolate the appliance from the gas supply 2 Allow oil to cool...

Страница 14: ...he pilot position Yes Check over temperature stat for open circuit and then check thermocouple voltage min 15mv Yes Very Little Check supply then check pilot jet for blockages and clean if necessary N...

Страница 15: ...minimum amount of time to ensure fryer does not get too hot 4 Turn the thermostat to off and ensure the burner has extinguished completely within 3 4 seconds 5 Turn the thermostat on again to 150 C a...

Страница 16: ...Exploded View INST REF IN274 3 DATE 09 07 19 16 Exploded View Main Assembly Burner Assembly...

Страница 17: ...yer Basket BASKETGFR 11 Plastic Handle HANDLBASK 12 Lid NO CODE 13 Tee Knob TEEKNOB 14 Flue Cover NO CODE 15 Inner Flue NO CODE 16 12mm Equal Tee FRYERTE12 16a 12mm Equal Elbow GDF12ELBOW 17 12mm Inle...

Страница 18: ...CT0230 LPG Gas INJECT0160 6 Over Temperature Thermostat TMST07000 7 Burner BURNR7000 8 Universal Thermocouple THCP900MM 9 Pilot Assembly cw Electrode PILOT7000 10 Pilot Injector NAT Gas PINJ76378 LPG...

Страница 19: ...the thermostat where necessary is made by the screw in the centre of the thermostat spindle Clockwise to decrease temperature Anti clockwise to increase CONTROL VALVE 1 Disconnect the gas supply pipe...

Страница 20: ...ill result in your warranty being put on hold until the bill has been settled Any issues regarding the raised charges should be put in writing to our warranty department for further investigation Regi...